FTXTM30M2V1B / RXTM30N2V1B FTXTM40M2V1B / RXTM40N2V1B
Indoor unit FTXTM30M2V1B FTXTM40M2V1B
Outdoor unit RXTM30N2V1B RXTM40N2V1B
Cooling capacity Min. kW 0.70 0.70
  Min. Btu/h 2,380 2,380
  Min. kcal/h 601 601
  Nom. kW 3.00 4.00
  Nom. Btu/h 10,230 13,640
  Nom. kcal/h 2,579 3,439
  Max. kW 4.50 5.10
  Max. Btu/h 15,350 17,400
  Max. kcal/h 3,869 4,385
Heating capacity Min. kW 0.80 0.80
  Min. Btu/h 2,720 2,720
  Min. kcal/h 687 687
  Nom. kW 3.20 4.00
  Nom. Btu/h 10,910 13,640
  Nom. kcal/h 2,751 3,439
  Max. kW 6.70 7.20
  Max. Btu/h 22,860 24,560
  Max. kcal/h 5,760 6,190
Power input Cooling Nom. kW 0.74 1.09
  Heating Nom. kW 0.61 0.78
Nominal efficiency EER   4.10 3.71
  COP   5.34 5.37
  Annual energy consumption kWh 366 (0.000) 542 (0.000)
  Energy labeling Directive Cooling   A A
    Heating   A A
Space cooling Capacity Pdesign kW 3.00 4.00
  Energy efficiency class   A++ A++
  SEER   7.60 7.70
  Annual energy consumption kWh/a 138 182
  A Condition (35°C - 27/19) Pdc kW 3.00 4.00
    EERd   4.10 3.71
    Power input kW 0.73 1.08
  B Condition (30°C - 27/19) Pdc kW 2.21 2.95
    EERd   5.65 5.69
    Power input kW 0.39 0.52
  C Condition (25°C - 27/19) Pdc kW 1.42 1.89
    EERd   9.31 9.49
    Power input kW 0.15 0.20
  D Condition (20°C - 27/19) Pdc kW 1.43 1.45
    EERd   12.80 13.03
    Power input kW 0.11 0.12
Space heating (Average climate) Capacity Pdesign kW 3.00 3.80
  Energy efficiency class   A+++ A+++
  SCOP/A   5.12 5.30
  SCOPnet/A   5.13 5.31
  Pdh Heating capacity at -10° kW 3.00 3.80
  Annual energy consumption kWh/a 821 1,004
  Required back up heating cap at design conditions kW 0.00 0.00
  TOL Tol (temperature operating limit) °C -25 -25
    Pdh (declared heating cap) kW 3.60 4.00
    COPd (declared COP)   1.65 1.90
    Power input kW 2.18 1.92
  TBivalent Tbiv (bivalent temperature) °C -10 -10
    Pdh (declared heating cap) kW 3.00 3.80
    COPd (declared COP)   2.62 2.30
    Power input kW 1.15 1.65
  A Condition (-7°C) Pdh (declared heating cap) kW 2.65 3.36
    COPd (declared COP)   3.28 3.53
    Power input kW 0.81 0.95
  B Condition (2°C) Pdh (declared heating cap) kW 1.62 2.05
    COPd (declared COP)   5.34 5.36
    Power input kW 0.30 0.38
  C Condition (7°C) Pdh (declared heating cap) kW 1.04 1.32
    COPd (declared COP)   6.07 6.60
    Power input kW 0.17 0.20
  D Condition (12°C) Pdh (declared heating cap) kW 1.10 1.49
    COPd (declared COP)   7.72 8.11
    Power input kW 0.14 0.18
Space heating (Cold climate) Capacity Pdesignh kW 4.40 5.60
  Energy efficiency class   A+ A+
  SCOP/C   4.02 4.19
  SCOPnet/C   4.08 4.27
  Annual energy consumption kWh/a 2,296 2,779
  Required back up heating cap at design conditions kW 0.70 1.30
  TOL Tol (temperature operating limit) °C -25 -25
    Pdh (declared heating cap) kW 3.60 4.00
    COPd (declared COP)   1.65 1.90
    Power input kW 2.18 1.92
  TBivalent Tbiv (bivalent temperature) °C -15 -15
    Pdh (declared heating cap) kW 3.59 4.53
    COPd (declared COP)   1.98 2.14
    Power input kW 1.81 2.12
  A Condition (-15°C) Pdh (declared heating cap) kW 3.59 4.53
    COPd (declared COP)   1.98 2.14
    Power input kW 1.81 2.12
  A Condition (-7°C) Pdh (declared heating cap) kW 2.65 3.36
    COPd (declared COP)   3.28 3.53
    Power input kW 0.81 0.95
  B Condition (2°C) Pdh (declared heating cap) kW 1.62 2.05
    COPd (declared COP)   5.34 5.36
    Power input kW 0.30 0.38
  C Condition (7°C) Pdh (declared heating cap) kW 1.04 1.32
    COPd (declared COP)   6.07 6.60
    Power input kW 0.17 0.20
  D Condition (12°C) Pdh (declared heating cap) kW 1.10 1.49
    COPd (declared COP)   7.72 8.11
    Power input kW 0.14 0.18
Power consumption in other than active mode Thermostat-off mode PTO Cooling W 7.0 7.0
      Heating W 12.0 15.0
  Crankcase heater mode PCK W 0.0 0.0
  Off mode POFF W 1.0 1.0
  Standby mode Cooling PSB W 1.0 1.0
    Heating PSB W 1.0 1.0
Cooling Cdc (Degradation cooling)   0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25
Cooling function included Yes Yes
Heating function included Yes Yes
Average climate included Yes Yes
Cold season included Yes Yes
Warm season included No No
Ecolabel logo No No
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61
  Sound power level indoor Cooling Nom. dBA 60 60
  Piping length Cooling Measuring condition m 5 5
Power factor Nominal Cooling % 98.16 (0.000) 98.32 (0.000)
    Heating % 94.03 (0.000) 97.56 (0.000)
Current Nominal running current (RLA) - 50Hz Cooling A 3.30 4.83
    Heating A 2.83 3.50
Notes See separate drawing for electrical data See separate drawing for electrical data
  Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W]
  Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.