EHVH04S23DAV / ERGA04DAV3 |
EHVH08S23DAV / ERGA06DAV3 |
EHVH08S23DAV / ERGA08DAV3 |
Heating capacity |
Nom. |
kW |
4.30 (1), 4.60 (2) |
6.00 (1), 5.90 (2) |
7.50 (1), 7.80 (2) |
Power input |
Heating |
Nom. |
kW |
0.850 (1), 1.26 (2) |
1.24 (1), 1.69 (2) |
1.63 (1), 2.23 (2) |
|
Domestic hot water from 10°C to 50°C |
Nom. |
kWh |
3.01 (0.000) |
3.01 (0.000) |
3.01 (0.000) |
Heat up time from 10°C to 50°C |
hr |
1h40min |
1h40min |
1h40min |
COP |
5.10 (1), 3.65 (2) |
4.85 (1), 3.50 (2) |
4.60 (1), 3.50 (2) |
Domestic hot water heating |
General |
Declared load profile |
|
XL |
XL |
XL |
|
Average climate |
Water heating energy efficiency class |
|
A+ |
A+ |
A+ |
Space heating |
Average climate water outlet 55°C |
General |
SCOP |
|
3.26 |
3.26 |
3.32 |
|
|
|
Seasonal space heating eff. class |
|
A++ |
A++ |
A++ |
|
Average climate water outlet 35°C |
General |
SCOP |
|
4.48 |
4.47 |
4.56 |
|
|
|
Seasonal space heating eff. class |
|
A++ |
A++ |
A++ |
Notes |
Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
|
Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |