| AHQ71CV1 / AZQS71B2V1B | AHQ100CV1 / AZQS100B8V1B | AHQ125CV1 / AZQS125B8V1B | AHQ140CV1 / AZQS140B8V1B | ||||
|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 6.8 | 9.5 | 12.1 (1) | 13.0 (1) | |
| Space cooling | SEER | 4.65 | 4.60 | 5.14 | 5.77 | ||
| Annual energy consumption | kWh/a | 511.85 | 723 | 1,412 | 1,353 | ||
| Capacity | Pdesign | kW | 6.80 | 9.50 | 12.1 | 13.0 | |
| Energy efficiency class | B | B | |||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 6.33 | 7.60 | 8.0 | 12.0 |
| SCOP/A | 3.80 | 3.80 | 3.78 | 3.99 | |||
| Energy efficiency class | A | A | |||||
| Annual energy consumption | kWh/a | 2,332.26 | 2,800 | 2,964 | 4,199 | ||
| Nominal efficiency | EER | 3.03 | 2.62 | 2.22 (3) | 2.63 (3) | ||
| Annual energy consumption | kWh | 1,120 | 1,810 | ||||
| COP | 3.05 | 3.41 | |||||
| Energy labeling Directive | Cooling | B | D | ||||
| Heating | D | B | |||||
| Heating capacity | Nom. | kW | 7.5 | 10.8 | 13.5 (2) | 15.5 (2) | |
| Notes | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | |||
| (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | ||||
| (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (3) - EER/COP according to Eurovent 2012, for use outside EU only | (3) - EER/COP according to Eurovent 2012, for use outside EU only | |||||
| (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2 | |||||||
| (5) - See separate drawing for electrical data | |||||||
| (6) - Contains fluorinated greenhouse gases | |||||||