| ARXM25M2V1B | ARXM35M2V1B | ARXM50MV1B | |||||
|---|---|---|---|---|---|---|---|
| Dimensions | Unit | Height | mm | 550 | 550 | 735 | |
| Width | mm | 765 | 765 | 825 | |||
| Depth | mm | 285 | 285 | 300 | |||
| Weight | Unit | kg | 32 | 32 | 44 | ||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | |||
| Operation range | Cooling | Ambient | Min. | °CDB | -10 | -10 | -10 |
| Max. | °CDB | 46 | 46 | 46 | |||
| Heating | Ambient | Min. | °CWB | -15 | -15 | -15 | |
| Max. | °CWB | 18 | 18 | 18 | |||
| Sound pressure level | Cooling | High | dBA | 46 | 49 | 48 | |
| Low | dBA | 44 | |||||
| Heating | High | dBA | 47 | 49 | 49 | ||
| Low | dBA | 45 | |||||
| Refrigerant | Type | R-32 | R-32 | R-32 | |||
| Charge | kg | 0.76 | 0.76 | 1.4 | |||
| Charge | tCO2Eq | 0.5 | 0.5 | 0.9 | |||
| GWP | 675 | 675 | 675 | ||||
| Piping connections | Piping length | OU - IU | Max. | m | 15 | 15 | 30 |
| Additional refrigerant charge | kg/m | 0.02 (for piping length exceeding 10m) | 0.02 (for piping length exceeding 10m) | 0.02 (for piping length exceeding 10m) | |||
| Level difference | IU - OU | Max. | m | 12 | 12 | 20 | |
| Standard Accessories | Installation manual | 1 | 1 | 1 | |||
| Refrigerant charge label | 1 | 1 | 1 | ||||
| Multilingual fluorinated greenhouse gases labels | 1 | 1 | 1 | ||||
| Drain plug (only heat pump models) | 1 | 1 | 1 | ||||
| Power supply | Phase | 1~ | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | 220-240 | |||