Specifications Table for CTXS-K

CTXS15K2V1B CTXS15K3V1B CTXS35K2V1B CTXS35K3V1B
Fan Air flow rate Cooling Nom. m³/min 6.3   7.2
Sound pressure level Cooling Nom. dBA 31   35
Fan Air flow rate Heating Nom. m³/min 7.5   8.1
Sound pressure level Heating Nom. dBA 33
Power input Cooling Nom. kW 0.04 0.04 0.040 0.040
  Heating Nom. kW 0.04 0.04 0.040 0.040
Casing Colour   White White White White
Dimensions Unit Height mm 289 289 289 289
    Width mm 780 780 780 780
    Depth mm 215 215 215 215
Weight Unit kg 8 8 8 8.00
Fan Air flow rate Cooling High m³/min 7.9 7.9 9.2 9.2
      Medium m³/min   6.3   7.2
      Low m³/min 4.7 4.7 5.2 5.2
      Silent operation m³/min 3.9 3.9 3.9 3.9
    Heating High m³/min 9 9 10.1 10.1
      Medium m³/min   7.5   8.1
      Low m³/min 6 6 6.3 6.3
      Silent operation m³/min 4.3 4.3 4.3 4.3
Sound power level Cooling dBA 55 55 59 59
  Heating dBA 56 56 58 58
Sound pressure level Cooling High dBA 37 37 42 42
    Medium dBA   31   35
    Low dBA 25 25 28 28
    Silent operation dBA 21 21 21 21
  Heating High dBA 38 38 41 41
    Medium dBA   33   36
    Low dBA 28 28 30 30
    Silent operation dBA 21 21 21 21
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 9.5 9.50
  Drain   18 18 18 18
Control systems Infrared remote control   ARC466A6 ARC466A6 ARC466A6 ARC466A6
Standard Accessories Installation manual 1 1 1 1
  Wireless remote control 1 1 1 1
  Operation manual 1 1 1 1
  Batteries 2   2
  Indoor unit fixing screws 2 2 2 2
  Mounting plate 1 1 1 1
  Remote control holder 1 1 1 1
  Titanium apatite photocatalytic air purification filter 2   2
Power supply Name   V1 V1 V1 V1
  Phase   1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240
Notes (1) - 220V (1) - 220V (1) - 220V (1) - 220V
  (2) - 230V (2) - 230V (2) - 230V (2) - 230V
  (3) - 240V (3) - 240V (3) - 240V (3) - 240V
Standard Accessories AAA dry-cell batteries   2   2
  Titanium apatite deodorizing filter   2   2
Notes   (4) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.   (4) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.