| EBVZ16S18DJ6V / ERLA16DAW1 | EBVZ16S23DJ6V / ERLA16DAW1 | |||||
|---|---|---|---|---|---|---|
| Domestic hot water heating | General | Declared load profile | L | XL | ||
| Average climate | Water heating energy efficiency class | A+ | A | |||
| COP | 4.53 (1), 3.51 (2) | 4.53 (1), 3.51 (2) | ||||
| Space heating | Average climate water outlet 35°C | General | ηs (Seasonal space heating efficiency) | % | 181 | 181 |
| Seasonal space heating eff. class | A+++ | A+++ | ||||
| SCOP | 4.61 | 4.61 | ||||
| Average climate water outlet 55°C | General | Seasonal space heating eff. class | A++ | A++ | ||
| ηs (Seasonal space heating efficiency) | % | 130 | 130 | |||
| SCOP | 3.32 | 3.32 | ||||
| Heat up time from 10°C to 50°C | hr | 1h15min at 7°C ambient temperature | 1h15min at 7°C ambient temperature | |||
| Heating capacity | Nom. | kW | 16.0 (1), 16.0 (2) | 16.0 (1), 16.0 (2) | ||
| Power input | Heating | Nom. | kW | 3.53 (1), 4.56 (2) | 3.53 (1), 4.56 (2) | |
| Domestic hot water from 10°C to 50°C | Nom. | kWh | 2.44 | 3.41 | ||
| Notes | (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | |||||
| (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | |||||
| (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | |||||
| (5) - According to EN14825 | (5) - According to EN14825 | |||||
| (6) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (6) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (7) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (7) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| (8) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (8) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | |||||