| EDLA16DA3W1 | |||||
|---|---|---|---|---|---|
| Heating capacity | Nom. | kW | 16.0 | ||
| Heater capacity | Step 1 | kW | 3 | ||
| Power input | Heating | Nom. | kW | 3.53, 4.56 | |
| COP | 4.53, 3.51 | ||||
| Dimensions | Unit | Height | mm | 870 | |
| Width | mm | 1380 | |||
| Depth | mm | 460 | |||
| Weight | Unit | kg | 149 | ||
| Fan | Air flow rate | Heating | High | m³/min | 85.0 |
| Operation range | Heating | Water side | Min. | °C | 15 |
| Max. | °C | 60 | |||
| Domestic hot water | Ambient | Min. | °CDB | -25 | |
| Max. | °CDB | 35 | |||
| Water side | Min. | °C | 25 | ||
| Max. | °C | 55 | |||
| Refrigerant | Type | R-32 | |||
| GWP | 675.0 | ||||
| Charge | kg | 3.80 | |||
| Charge | tCO2Eq | 2.57 | |||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.33 | |
| Seasonal space heating eff. class | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 4.62 | ||
| Seasonal space heating eff. class | A+++ | ||||
| Compressor component | Main power supply | Phase | 3N~ | ||
| Voltage | V | 400 | |||
| Power supply | Name | W1 | |||
| Phase | 3~ | ||||
| Frequency | Hz | 50 | |||
| Voltage | V | 400 | |||
| Notes | (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | |||||
| (3) - For more details, see operation range drawing | |||||
| (4) - Depends on operation mode, refer to installation manual. | |||||