| EDLQ011CAV3 | EDLQ014CAV3 | EDLQ016CAV3 | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 51 (8) | 51 (8) | 52 (8) | |
| Cooling | Nom. | dBA | 50 (8) | 52 (8) | 54 (8) | ||
| Refrigerant | GWP | 2,087.5 | 2,087.5 | 2,087.5 | |||
| Charge | kg | 3.40 | 3.40 | 3.40 | |||
| Type | R-410A | R-410A | R-410A | ||||
| Operation range | Heating | Water side | Max. | °C | 55 (5) | 55 (5) | 55 (5) |
| Min. | °C | 25 (5) | 25 (5) | 25 (5) | |||
| Domestic hot water | Water side | Max. | °C | 80 (5) | 80 (5) | 80 (5) | |
| Min. | °C | 25 | 25 | 25 | |||
| Ambient | Min. | °CDB | -25 (5) | -25 (5) | -25 (5) | ||
| Max. | °CDB | 35 (5) | 35 (5) | 35 (5) | |||
| Cooling capacity | Nom. | kW | 12.4 (1), 11.6 (2) | 12.8 (1), 12.6 (2) | 13.9 (1), 13.6 (2) | ||
| Power input | Cooling | Nom. | kW | 3.18 (1), 5.09 (2) | 3.16 (1), 5.14 (2) | 3.56 (1), 5.96 (2) | |
| Heating | Nom. | kW | 2.43 (1), 3.10 (2) | 3.37 (1), 4.10 (2) | 3.76 (1), 4.66 (2) | ||
| Sound power level | Heating | Nom. | dBA | 64 (6) | 64 (6) | 66 (6) | |
| Cooling | Nom. | dBA | 64 (7) | 66 (7) | 69 (7) | ||
| COP | 4.61 (1), 3.55 (2) | 4.30 (1), 3.32 (2) | 4.26 (1), 3.26 (2) | ||||
| Dimensions | Unit | Width | mm | 1,160 | 1,160 | 1,160 | |
| Depth | mm | 380 | 380 | 380 | |||
| Height | mm | 1,348 | 1,348 | 1,348 | |||
| Weight | Unit | kg | 151 | 151 | 151 | ||
| Space heating | Average climate water outlet 35°C | General | ηs (Seasonal space heating efficiency) | % | 156 | 153 | 149 |
| Seasonal space heating eff. class | A++ | A++ | A+ | ||||
| SCOP | 3.98 | 3.90 | 3.80 | ||||
| Average climate water outlet 55°C | General | Seasonal space heating eff. class | A+ | A+ | A+ | ||
| ηs (Seasonal space heating efficiency) | % | 120 | 123 | 119 | |||
| SCOP | 3.09 | 3.16 | 3.06 | ||||
| Heater capacity | Step 1 | kW | 3 | 3 | 3 | ||
| Fan | Air flow rate | Heating | High | m³/min | 90.0 | 90.0 | 90.0 |
| Heating capacity | Nom. | kW | 11.2 (1), 11.0 (2) | 14.5 (1), 13.6 (2) | 16.0 (1), 15.2 (2) | ||
| Power supply | Phase | 1~ | 1~ | 1~ | |||
| Name | V3 | V3 | V3 | ||||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 230 | 230 | 230 | |||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | |||||
| (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | |||||
| (5) - Including BUH and / or booster heater. For more details see data-book | (5) - Including BUH and / or booster heater. For more details see data-book | (5) - Including BUH and / or booster heater. For more details see data-book | |||||
| (6) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (6) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (6) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (7) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | (7) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | (7) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | |||||
| (8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | |||||
| (9) - Including piping + PHE; excluding expansion vessel | (9) - Including piping + PHE; excluding expansion vessel | (9) - Including piping + PHE; excluding expansion vessel | |||||