| EGSQH10S18AA9W | |||||
|---|---|---|---|---|---|
| Heating capacity | Min. | kW | 3.11 (1), 2.47 (2) | ||
| Nom. | kW | 10.3 (1), 9.2 | |||
| Max. | kW | 13, 11.9 (2) | |||
| Power input | Nom. | kW | 2.38 (1), 2.89 (2) | ||
| COP | 4.33 (1), 3.18 (2) | ||||
| Casing | Colour | White | |||
| Material | Precoated sheet metal | ||||
| Dimensions | Unit | Height | mm | 1730 | |
| Width | mm | 600 | |||
| Depth | mm | 728 | |||
| Weight | Unit | kg | 210 | ||
| Tank | Water volume | l | 180 | ||
| Insulation | Heat loss | kWh/24h | 1.36 (4) | ||
| Corrosion protection | Anode | ||||
| Refrigerant | Type | R-410A | |||
| GWP | 2090 | ||||
| Charge | tCO2Eq | 3.76 | |||
| Charge | kg | 1.8 | |||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.68 | |
| Seasonal space heating eff. class | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 5.06 | ||
| Seasonal space heating eff. class | A+++ | ||||
| Energy Efficiency Range | Space Heating A+++ ~ D, Water Heating A+ ~ F | ||||
| Power supply | Name | 9W | |||
| Phase | 3~ | ||||
| Frequency | Hz | 50 | |||
| Voltage | V | 400 | |||
| Current | Recommended fuses | A | 25 | ||
| Notes | (1) - EWB/LWB 0°C/-3°C - LWC 35°C (DT=5°C) | ||||
| (2) - EWB/LWB 0°C/-3°C - LWC 45°C (DT=5°C) | |||||
| (3) - with 40% propylene glycol | |||||
| (4) - Heatloss according to EN12897 | |||||
| (5) - Including piping + PHE + back-up heater; excluding expansion vessel | |||||
| (6) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | |||||
| (7) - By heat pump | |||||
| (8) - By heat pump + back-up heater | |||||
| (9) - By back-up heater | |||||