| EHBX08EA9W / ERGA06EAV3 | EHBX08EF9W / ERGA06EAV3 | EHBX08EF9W / ERGA08EAV3 | EHBX08EA9W / ERGA08EAV3 | |||||
|---|---|---|---|---|---|---|---|---|
| Heating capacity | Nom. | kW | 6.00, 5.90 | 6.00, 5.90 | 7.50, 7.80 | 7.50, 7.80 | ||
| Cooling capacity | Nom. | kW | 5.96, 5.09 | 5.96, 5.09 | 6.25, 5.44 | 6.25, 5.44 | ||
| Power input | Heating | Nom. | kW | 1.24, 1.69 | 1.24, 1.69 | 1.63, 2.23 | 1.63, 2.23 | |
| Cooling | Nom. | kW | 1.06, 1.55 | 1.06, 1.55 | 1.16, 1.73 | 1.16, 1.73 | ||
| COP | 4.85, 3.50 | 4.85, 3.50 | 4.60, 3.50 | 4.60, 3.50 | ||||
| EER | 5.61, 3.28 | 5.61, 3.28 | 5.40, 3.14 | 5.40, 3.14 | ||||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.28 | 3.28 | 3.35 | 3.35 | |
| Seasonal space heating eff. class | A++ | A++ | A++ | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 4.52 | 4.52 | 4.61 | 4.61 | ||
| Seasonal space heating eff. class | A+++ | A+++ | A+++ | A+++ | ||||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| Energy Efficiency Range | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | ||||||