Specifications Table for EHSH-D / ERGA04-08DV

EHSH04P30DA / ERGA04DAV3 EHSH08P30DA / ERGA06DAV3 EHSH08P50DA / ERGA06DAV3 EHSH08P50DA7 / ERGA06DAV3 EHSH08P30DA / ERGA08DAV3 EHSH08P50DA / ERGA08DAV3 EHSH08P50DA7 / ERGA08DAV3
Domestic hot water heating General Declared load profile   L L XL   L XL
  Average climate Water heating energy efficiency class   A A A   A A
COP 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 4.85, 3.50 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2) 4.60, 3.50
Indoor unit EHSH04P30D EHSH08P30D EHSH08P50D EHSH08P50DA7 EHSH08P30D EHSH08P50D EHSH08P50DA7
Heating capacity Nom. kW 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2)   7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Power input Heating Nom. kW 0.850 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2)   1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
Notes (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
Heating capacity Nom. kW       6.00, 5.90     7.50, 7.80
Power input Heating Nom. kW       1.24, 1.69     1.63, 2.23
Domestic hot water heating General Declared load profile         XL     XL
  Average climate Water heating energy efficiency class         A     A
Space heating Average climate water outlet 55°C General SCOP         3.26     3.32
      Seasonal space heating eff. class         A++     A++
  Average climate water outlet 35°C General SCOP         4.47     4.56
      Seasonal space heating eff. class         A+++     A+++
Energy Efficiency Range       Space Heating A+++ ~ D, Water Heating A+ ~ F     Space Heating A+++ ~ D, Water Heating A+ ~ F