Specifications Table for EKEXVA

EKEXVA50 EKEXVA63 EKEXVA80 EKEXVA100 EKEXVA125 EKEXVA140 EKEXVA200 EKEXVA250 EKEXVA300 EKEXVA350 EKEXVA400 EKEXVA450 EKEXVA500
Dimensions Unit Height mm 404 404 404 404 404 404 404 404 404 404 404 404 404
    Width mm 217 217 217 217 217 217 217 217 217 217 217 217 217
    Depth mm 80.5 80.5 80.5 80.5 80.5 80.5 80.5 80.5 80.5 80.5 80.5 80.5 80.5
Weight Unit kg 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9
Sound pressure level Cooling Nom. dBA 36.5 37.5 38.6 39.5 40.5 41.1 42.5 43.5 44.3 45.1 45.6 46.1 46.5
  Heating Nom. dBA 24.8 25.8 26.8 27.8 28.8 29.4 30.8 31.8 32.5 33.3 33.8 34.3 34.8
Refrigerant Type   R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A R32/R410A
Piping connections Liquid Type   Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected) Braze connection (only liquid line connected)
    OD mm 6.40 6.40 6.40 9.52 9.52 9.52 9.52 9.52 12.7 12.7 12.7 12.7 12.7
Notes (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations (1) - Refer to outdoor unit refrigerant pipe selection drawing for piping length and level difference limitations
Standard Accessories Connection pipes   2 2                 2 2