| EKHBRD011ADV1 | EKHBRD014ADV1 | EKHBRD016ADV1 | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Nom. | dBA | 43.0 (3), 46.0 (4), 0.00 (5), 0.00 (6) | 45.0 (3), 46.0 (4), 0.00 (5), 0.00 (6) | 46.0 (3), 46.0 (4), 0.00 (5), 0.00 (6) | ||
| Refrigerant | Charge | TCO2Eq | 3,718.000 | 3,718.000 | 3,718.000 | ||
| GWP | 1,430 | 1,430 | 1,430 | ||||
| Charge | kg | 2.60 | 2.60 | 2.60 | |||
| Type | R-134a | R-134a | R-134a | ||||
| Operation range | Heating | Water side | Max. | °C | 80.0 | 80.0 | 80.0 |
| Min. | °C | 25 | 25 | 25 | |||
| Dimensions | Unit | Width | mm | 600 | 600 | 600 | |
| Depth | mm | 695 | 695 | 695 | |||
| Height | mm | 705 | 705 | 705 | |||
| Casing | Material | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | |||
| Colour | Metallic grey | Metallic grey | Metallic grey | ||||
| Weight | Unit | kg | 144 | 144 | 144 | ||
| PED | Category | Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||
| Power supply | Phase | 1~ | 1~ | 1~ | |||
| Name | V1 | V1 | V1 | ||||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | 220-240 | |||
| Current | Recommended fuses | A | 25 | 25 | 25 | ||
| Notes | (1) - Nominal water flow rate for Dt: 10°C | (1) - Nominal water flow rate for Dt: 10°C | (1) - Nominal water flow rate for Dt: 10°C | ||||
| (2) - Maximum water flow rate for Dt: 5°C | (2) - Maximum water flow rate for Dt: 5°C | (2) - Maximum water flow rate for Dt: 5°C | |||||
| (3) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (3) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (3) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | |||||
| (4) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (4) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (4) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | |||||
| (5) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. | (5) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. | (5) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. | |||||
| (6) - EW = entering water temperature - LW = leaving water temperature | (6) - EW = entering water temperature - LW = leaving water temperature | (6) - EW = entering water temperature - LW = leaving water temperature | |||||
| (7) - Outdoor ambient, indoor ambient: 5°C~30°C | (7) - Outdoor ambient, indoor ambient: 5°C~30°C | (7) - Outdoor ambient, indoor ambient: 5°C~30°C | |||||
| (8) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C | (8) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C | (8) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C | |||||
| (9) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (9) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (9) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | |||||
| (10) - European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A. | (10) - European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A. | (10) - European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A. | |||||
| (11) - Zsys: system impedance | (11) - Zsys: system impedance | (11) - Zsys: system impedance | |||||
| (12) - Equipment complying with EN/IEC 61000-3-12 | (12) - Equipment complying with EN/IEC 61000-3-12 | (12) - Equipment complying with EN/IEC 61000-3-12 | |||||
| (13) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. | (13) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. | (13) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. | |||||
| (14) - Short-circuit power | (14) - Short-circuit power | (14) - Short-circuit power | |||||
| (15) - Contains fluorinated greenhouse gases | (15) - Contains fluorinated greenhouse gases | (15) - Contains fluorinated greenhouse gases | |||||