| EKHBRD011ADV17 | EKHBRD014ADV17 | EKHBRD016ADV17 | |||||
|---|---|---|---|---|---|---|---|
| Casing | Colour | Metallic grey | Metallic grey | Metallic grey | |||
| Material | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | ||||
| Dimensions | Unit | Height | mm | 705 | 705 | 705 | |
| Width | mm | 600 | 600 | 600 | |||
| Depth | mm | 695 | 695 | 695 | |||
| Weight | Unit | kg | 144 | 144 | 144 | ||
| PED | Category | Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||
| Refrigerant | Type | R-134a | R-134a | R-134a | |||
| Charge | kg | 2.6 | 2.6 | 2.6 | |||
| Sound power level | Nom. | dBA | 59 | 60 | 60 | ||
| Sound pressure level | Nom. | dBA | 43, 46, 0, 0 | 45, 46, 0, 0 | 46, 46, 0, 0 | ||
| Operation range | Heating | Water side | Min. | °C | 25 | 25 | 25 |
| Max. | °C | 80.0 | 80.0 | 80.0 | |||
| Power supply | Name | V1 | V1 | V1 | |||
| Phase | 1~ | 1~ | 1~ | ||||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | 220-240 | |||
| Current | Recommended fuses | A | 25 | 25 | 25 | ||
| Notes | (1) - Nominal water flow rate for Dt: 10°C | (1) - Nominal water flow rate for Dt: 10°C | (1) - Nominal water flow rate for Dt: 10°C | ||||
| (2) - Maximum water flow rate for Dt: 5°C | (2) - Maximum water flow rate for Dt: 5°C | (2) - Maximum water flow rate for Dt: 5°C | |||||
| (3) - Sound pressure level is measured in accordance with ISO3744. Sound power level is calculated from sound pressure level. | (3) - Sound pressure level is measured in accordance with ISO3744. Sound power level is calculated from sound pressure level. | (3) - Sound pressure level is measured in accordance with ISO3744. Sound power level is calculated from sound pressure level. | |||||
| (4) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (4) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (4) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | |||||
| (5) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (5) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | (5) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | |||||
| (6) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. | (6) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. | (6) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. | |||||
| (7) - EW = entering water temperature - LW = leaving water temperature | (7) - EW = entering water temperature - LW = leaving water temperature | (7) - EW = entering water temperature - LW = leaving water temperature | |||||
| (8) - Outdoor ambient, indoor ambient: 5°C~30°C | (8) - Outdoor ambient, indoor ambient: 5°C~30°C | (8) - Outdoor ambient, indoor ambient: 5°C~30°C | |||||
| (9) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C | (9) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C | (9) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C | |||||