| ELBX12EF9W / ERRA08EAW1 | ELBX12EF9W / ERRA10EAW1 | ELBX12EF9W / ERRA12EAW1 | |||||
|---|---|---|---|---|---|---|---|
| Heating capacity | Min. | kW | 3.45 | 3.45 | 3.45 | ||
| Nom. | kW | 6.17 | 6.17 | 6.17 | |||
| Max. | kW | 7.95 | 9.25 | 9.97 | |||
| Cooling capacity | Nom. | kW | 6.81, 6.47 | 7.97, 6.47 | 8.62, 6.47 | ||
| Power input | Heating | Min. | kW | 0.70 | 0.70 | 0.70 | |
| Nom. | kW | 1.21 | 1.21 | 1.21 | |||
| Max. | kW | 1.63 | 1.98 | 2.21 | |||
| Cooling | Nom. | kW | 2.08, 1.13 | 2.57, 1.13 | 2.86, 1.13 | ||
| COP | 5.10 | 5.10 | 5.10 | ||||
| EER | 3.28, 5.75 | 3.10, 5.75 | 3.01, 5.75 | ||||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.47 | 3.48 | 3.58 | |
| Seasonal space heating eff. class | A++ | A++ | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 4.95 | 4.98 | 4.98 | ||
| Seasonal space heating eff. class | A+++ | A+++ | A+++ | ||||
| Notes | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | ||||
| (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | |||||
| (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | |||||
| (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | |||||
| (6) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (6) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (6) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | |||||