| ELSX12P50EF / ERRA08EAV3 | ELSX12P30EF / ERRA08EAV3 | ELSX12P30EF / ERRA10EAV3 | ELSX12P50EF / ERRA10EAV3 | ELSX12P30EF / ERRA12EAV3 | ELSX12P50EF / ERRA12EAV3 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Heating capacity | Min. | kW | 3.45 | 3.45 | 3.45 | 3.45 | 3.45 | 3.45 | ||
| Nom. | kW | 6.17 | 6.17 | 6.17 | 6.17 | 6.17 | 6.17 | |||
| Max. | kW | 7.95 | 7.95 | 9.25 | 9.25 | 9.97 | 9.97 | |||
| Cooling capacity | Nom. | kW | 6.81, 6.47 | 6.81, 6.47 | 7.97, 6.47 | 7.97, 6.47 | 8.62, 6.47 | 8.62, 6.47 | ||
| Power input | Heating | Min. | kW | 0.72 | 0.72 | 0.72 | 0.72 | 0.72 | 0.72 | |
| Nom. | kW | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |||
| Max. | kW | 1.69 | 1.69 | 2.04 | 2.04 | 2.28 | 2.28 | |||
| Cooling | Nom. | kW | 2.15, 1.16 | 2.15, 1.16 | 2.66, 1.16 | 2.66, 1.16 | 2.96, 1.16 | 2.96, 1.16 | ||
| Domestic hot water from 10°C to 50°C | Nom. | kWh | 4.82 | 3.57 | 3.57 | 4.82 | 3.57 | 4.82 | ||
| Heat up time from 10°C to 50°C | hr | 3h45min | 2h29min | 2h29min | 3h45min | 2h29min | 3h45min | |||
| COP | 4.92 | 4.92 | 4.92 | 4.92 | 4.92 | 4.92 | ||||
| EER | 3.17, 5.56 | 3.17, 5.56 | 3.00, 5.56 | 3.00, 5.56 | 2.91, 5.56 | 2.91, 5.56 | ||||
| Domestic hot water heating | General | Declared load profile | XL | L | L | XL | L | XL | ||
| Average climate | Water heating energy efficiency class | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.37 | 3.37 | 3.38 | 3.38 | 3.47 | 3.47 | |
| Seasonal space heating eff. class | A++ | A++ | A++ | A++ | A++ | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 4.79 | 4.79 | 4.82 | 4.82 | 4.82 | 4.82 | ||
| Seasonal space heating eff. class | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||
| Notes | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | ||||
| (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | |||||
| (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | |||||
| (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | |||||
| (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | |||||
| (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | |||||