EPVX14S18AJ4V / EPSK12ARW1 |
EPVX14S23AJ4V / EPSK12ARW1 |
EPVX14S18AJ4V / EPSK14ARW1 |
EPVX14S23AJ4V / EPSK14ARW1 |
Indoor unit
|
EPVX14S18AJ4V
|
EPVX14S23AJ4V
|
EPVX14S18AJ4V
|
EPVX14S23AJ4V
|
Heating capacity
|
Nom.
|
kW
|
10.2 (1)
|
10.2 (1)
|
10.2 (1)
|
10.2 (1)
|
|
Max.
|
kW
|
11.99 (2)
|
11.99 (2)
|
13.34 (2)
|
13.34 (2)
|
Cooling capacity
|
Nom.
|
kW
|
9.37 (3), 6.74 (4)
|
9.37 (3), 6.74 (4)
|
11.3 (3), 6.74 (4)
|
11.3 (3), 6.74 (4)
|
Power input
|
Heating
|
Nom.
|
kW
|
1.86 (1)
|
1.86 (1)
|
1.86 (1)
|
1.86 (1)
|
|
|
Max.
|
kW
|
3.51 (5)
|
3.51 (5)
|
3.98 (5)
|
3.98 (5)
|
|
Cooling
|
Nom.
|
kW
|
2.64 (3), 1.12 (4)
|
2.64 (3), 1.12 (4)
|
3.45 (3), 1.12 (4)
|
3.45 (3), 1.12 (4)
|
|
Domestic hot water from 10°C to 50°C
|
Nom.
|
kWh
|
2.24
|
2.54
|
2.24
|
2.54
|
Heat up time from 10°C to 50°C
|
hr
|
1h 17min
|
1h 30min
|
1h 17min
|
1h 30min
|
COP
|
5.50 (1)
|
5.50 (1)
|
5.50 (1)
|
5.50 (1)
|
EER
|
3.55 (3), 6.04 (4)
|
3.55 (3), 6.04 (4)
|
3.28 (3), 6.04 (4)
|
3.28 (3), 6.04 (4)
|
Domestic hot water heating
|
General
|
Declared load profile
|
|
L
|
L
|
L
|
L
|
|
Average climate
|
Water heating energy efficiency class
|
|
A+
|
A+
|
A+
|
A+
|
Space heating
|
Average climate water outlet 55°C
|
General
|
SCOP
|
|
4.04
|
4.04
|
3.84
|
3.84
|
|
|
|
Seasonal space heating eff. class
|
|
A+++
|
A+++
|
A+++
|
A+++
|
|
Average climate water outlet 35°C
|
General
|
SCOP
|
|
5.14
|
5.14
|
4.96
|
4.96
|
|
|
|
Seasonal space heating eff. class
|
|
A+++
|
A+++
|
A+++
|
A+++
|
Notes
|
(1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
|
(2) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
|
(2) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
|
(2) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
|
(2) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
|
|
(3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
(3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
(3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
(3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
|
(4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
(4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
(4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
(4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
|
(5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
|
(5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
|
(5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
|
(5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
|