Specifications Table for ERLA-DV37

ERLA16D2V37 ERLA16DAV37
Dimensions Unit Height mm 870 870
    Width mm 1100 1100
    Depth mm 460 460
Weight Unit kg 101 101
Fan Air flow rate Heating High m³/min 85.0 85.0
    Cooling High m³/min 85 85
Operation range Cooling Min. °CDB 10 10
    Max. °CDB 43 43
  Domestic hot water Min. °CDB -25 -25
    Max. °CDB 25 (1), 35 (1) 25 (1), 35 (1)
Sound power level Heating Nom. dBA 62.0 (2) 62.0 (2)
Sound pressure level Heating Nom. dBA 48.0 (2) 48.0 (2)
Refrigerant Type   R-32 R-32
  GWP   675.0 675.0
  Charge tCO2Eq 2.57 2.57
  Charge kg 3.8 3.8
Piping connections Liquid OD mm 9.5 9.5
  Gas OD mm 15.9 15.9
  Drain OD mm 26 26
  Level difference IU - OU Max. m 30.0 30.0
  Heat insulation   Both liquid and gas pipes Both liquid and gas pipes
Power supply Name   V3 V3
  Phase   1~ 1~
  Frequency Hz 50 50
  Voltage V 230 230
Current Recommended fuses A 32 32
Notes (1) - For more details, see operation range drawing (1) - For more details, see operation range drawing
  (2) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (2) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.