Specifications Table for ETBH-D6V / EPRA014-018DW

ETBH16DA6V / EPRA14DAW1 ETBH16DF6V / EPRA14DAW1 ETBH16DA6V / EPRA16DAW1 ETBH16DF6V / EPRA16DAW1 ETBH16DA6V / EPRA18DAW1 ETBH16DF6V / EPRA18DAW1
Indoor unit ETBH16DA6V ETBH16DA6V ETBH16DA6V ETBH16DA6V ETBH16DA6V ETBH16DA6V
Heating capacity Min. kW 3.70 3.70 3.96 3.96 4.40 4.40
  Nom. kW 5.90 5.90 9.00 9.00 9.00 9.00
  Max. kW 9.75 9.75 10.44 10.44 11.60 11.60
Power input Heating Min. kW 0.84 0.84 0.90 0.90 1.00 1.00
    Nom. kW 1.23 1.23 1.80 1.80 1.80 1.80
    Max. kW 2.17 2.17 2.32 2.32 2.58 2.58
COP 4.79 4.79 5.00 5.00 5.00 5.00
Space heating Average climate water outlet 55°C General SCOP   3.57 3.57 3.57 3.57 3.57 3.57
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.71 4.71 4.71 4.71 4.71 4.71
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++ A+++
Notes (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
  (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed