Specifications Table for ETSH16E7 / EPRA14-18DW7

ETSH16P50EF7 / EPRA14DAW17 ETSH16P30EF7 / EPRA14DAW17 ETSH16P30EF7 / EPRA14DBW17 ETSH16P50EF7 / EPRA14DBW17 ETSH16P30EF7 / EPRA16DAW17 ETSH16P50EF7 / EPRA16DAW17 ETSH16P30EF7 / EPRA16DBW17 ETSH16P50EF7 / EPRA16DBW17 ETSH16P30EF7 / EPRA18DAW17 ETSH16P50EF7 / EPRA18DAW17 ETSH16P30EF7 / EPRA18DBW17 ETSH16P50EF7 / EPRA18DBW17
Heating capacity Min. kW 3.70 3.70 3.70 3.70 3.96 3.96 3.96 3.96 4.40 4.40 4.40 4.40
  Nom. kW 5.90 5.90 5.90 5.90 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00
  Max. kW 9.75 9.75 9.75 9.75 10.44 10.44 10.44 10.44 11.60 11.60 11.60 11.60
Power input Heating Min. kW 0.84 0.84 0.84 0.84 0.90 0.90 0.90 0.90 1.00 1.00 1.00 1.00
    Nom. kW 1.23 1.23 1.23 1.23 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80
    Max. kW 2.17 2.17 2.17 2.17 2.32 2.32 2.32 2.32 2.58 2.58 2.58 2.58
COP 4.79 4.79 4.79 4.79 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
Domestic hot water heating General Declared load profile   XL L L XL L XL L XL L XL L XL
  Average climate Water heating energy efficiency class   A+ A+ A+ A+ A+ A+ A+ A+ A+ A+ A+ A+
Space heating Average climate water outlet 55°C General SCOP   3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Notes (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511