Specifications Table for ETSHB-D / EPRA014-018DV

ETSHB16P50DA / EPRA14DAV3 ETSHB16P30DA / EPRA14DAV3 ETSHB16P50DA / EPRA16DAV3 ETSHB16P30DA / EPRA16DAV3 ETSHB16P50DA / EPRA18DAV3 ETSHB16P30DA / EPRA18DAV3
Indoor unit ETSHB16P50DA ETSHB16P30DA ETSHB16P50DA ETSHB16P30DA ETSHB16P50DA ETSHB16P30DA
Heating capacity Min. kW 3.70 3.70 3.96 3.96 4.40 4.40
  Nom. kW 5.69 5.69 9.00 9.00 9.00 9.00
  Max. kW 10.18 10.18 10.91 10.91 12.12 12.12
Power input Heating Min. kW 0.88 0.88 0.95 0.95 1.05 1.05
    Nom. kW 1.22 1.22 1.80 1.80 1.80 1.80
    Max. kW 2.09 2.09 2.24 2.24 2.49 2.49
  Domestic hot water from 10°C to 50°C Nom. kWh 5.26 3.92 5.26 3.92 5.26 3.92
Heat up time from 10°C to 50°C hr 2h11min at 7°C ambient temperature 1h41min at 7°C ambient temperature 2h11min at 7°C ambient temperature 1h41min at 7°C ambient temperature 2h11min at 7°C ambient temperature 1h41min at 7°C ambient temperature
COP 4.67 4.67 5.00 5.00 5.00 5.00
Domestic hot water heating General Declared load profile   XL L XL L XL L
  Average climate Water heating energy efficiency class   A A A A A A
Space heating Average climate water outlet 55°C General SCOP   3.58 3.58 3.58 3.58 3.58 3.58
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.51 4.51 4.51 4.51 4.51 4.51
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++ A+++
Notes (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511