Specifications Table for ETVH-D9WG / EPRA014-018DW

ETVH16S18DA9WG / EPRA14DAW1 ETVH16S23DA9WG / EPRA14DAW1 ETVH16S18DA9WG / EPRA16DAW1 ETVH16S23DA9WG / EPRA16DAW1 ETVH16S18DA9WG / EPRA18DAW1 ETVH16S23DA9WG / EPRA18DAW1
Domestic hot water heating General Declared load profile   L XL L XL L
  Average climate Water heating energy efficiency class   A A A A A
COP 4.79 (2) 4.79 (2) 5.00 (2) 5.00 (2) 5.00 (2) 5.00
Indoor unit ETVH16S18DA9W ETVH16S23DA9W ETVH16S18DA9W ETVH16S23DA9W ETVH16S18DA9W ETVH16S23DA9W
Space heating Average climate water outlet 35°C General ηs (Seasonal space heating efficiency) % 186 186 186 186 186
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++
      SCOP   4.71 4.71 4.71 4.71 4.71
  Average climate water outlet 55°C General Seasonal space heating eff. class   A++ A++ A++ A++ A++
      ηs (Seasonal space heating efficiency) % 140 140 140 140 140
      SCOP   3.57 3.57 3.57 3.57 3.57
Heat up time from 10°C to 50°C hr 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature
Heating capacity Nom. kW 5.90 (2) 5.90 (2) 9.00 (2) 9.00 (2) 9.00 (2)
  Min. kW 3.70 (1) 3.70 (1) 3.96 (1) 3.96 (1) 4.40 (1)
  Max. kW 9.75 (1) 9.75 (1) 10.44 (1) 10.44 (1) 11.60 (1)
Power input Heating Max. kW 2.17 (5) 2.17 (5) 2.32 (5) 2.32 (5) 2.58 (5)
    Min. kW 0.84 (5) 0.84 (5) 0.90 (5) 0.90 (5) 1.00 (5)
    Nom. kW 1.23 (2) 1.23 (2) 1.80 (2) 1.80 (2) 1.80 (2)
  Domestic hot water from 10°C to 50°C Nom. kWh 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6) 2.57 (6)
Notes (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
  (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
  (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed
  (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
  (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed
Heating capacity Min. kW           4.40
  Nom. kW           9.00
  Max. kW           11.60
Power input Heating Min. kW           1.00
    Nom. kW           1.80
    Max. kW           2.58
  Domestic hot water from 10°C to 50°C Nom. kWh           2.85
Domestic hot water heating General Declared load profile             XL
  Average climate Water heating energy efficiency class             A
Space heating Average climate water outlet 55°C General SCOP             3.57
      Seasonal space heating eff. class             A++
  Average climate water outlet 35°C General SCOP             4.71
      Seasonal space heating eff. class             A+++