| ETVZ16S18EA9W7 | ETVZ16S18EJ9W7 | ETVZ16S23EJ9W7 | ETVZ16S23EA9W7 | |||||
|---|---|---|---|---|---|---|---|---|
| Casing | Material | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | |||
| Dimensions | Unit | Height | mm | 1650 | 1650 | 1850 | 1850 | |
| Width | mm | 595 | 595 | 595 | 595 | |||
| Depth | mm | 625 | 625 | 625 | 625 | |||
| Weight | Unit | kg | 120 | 120 | 128 | 128 | ||
| Sound power level | Nom. | dBA | 44.0 | 44.0 | 44.0 | 44.0 | ||
| Sound pressure level | Nom. | dBA | 30.0 | 30.0 | 30.0 | 30.0 | ||
| Operation range | Heating | Water side | Min. | °C | 0 | 0 | 0 | 0 |
| Max. | °C | 0 | 0 | 0 | 0 | |||
| Cooling | Ambient | Min. | °CDB | 0 | 0 | 0 | 0 | |
| Water side | Min. | °C | 0 | 0 | 0 | 0 | ||
| Max. | °C | 0 | 0 | 0 | 0 | |||
| Power supply | Name | See note 9 | See note 9 | See note 9 | See note 9 | |||
| Electric heater | Power supply | Name | 9W | 9W | 9W | 9W | ||
| Phase | 3~ | 3~ | 3~ | 3~ | ||||
| Frequency | Hz | 50 | 50 | 50 | 50 | |||
| Voltage | V | 400 | 400 | 400 | 400 | |||
| Recommended fuses | A | 20.000 | 20.000 | 20.000 | 20.000 | |||
| Notes | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | ||||
| (2) - Based on a dT of 45 K | (2) - Based on a dT of 45 K | (2) - Based on a dT of 45 K | (2) - Based on a dT of 45 K | |||||
| (3) - Including piping + back-up heater; excluding expansion vessel | (3) - Including piping + back-up heater; excluding expansion vessel | (3) - Including piping + back-up heater; excluding expansion vessel | (3) - Including piping + back-up heater; excluding expansion vessel | |||||
| (4) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | (4) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | (4) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | (4) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | |||||
| (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | |||||
| (6) - Value measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is measured with a pressure drop of 10 kPa in the heating system at an operatin | (6) - Value measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is measured with a pressure drop of 10 kPa in the heating system at an operatin | (6) - Value measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is measured with a pressure drop of 10 kPa in the heating system at an operatin | (6) - Value measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is measured with a pressure drop of 10 kPa in the heating system at an operatin | |||||
| (7) - Refer to operation range of the unit. | (7) - Refer to operation range of the unit. | (7) - Refer to operation range of the unit. | (7) - Refer to operation range of the unit. | |||||
| (8) - Depends on operation mode, refer to installation manual. | (8) - Depends on operation mode, refer to installation manual. | (8) - Depends on operation mode, refer to installation manual. | (8) - Depends on operation mode, refer to installation manual. | |||||
| (9) - 4 pole 20 A curve 400V tripping class C (refer to wiring diagram) | (9) - 4 pole 20 A curve 400V tripping class C (refer to wiring diagram) | (9) - 4 pole 20 A curve 400V tripping class C (refer to wiring diagram) | (9) - 4 pole 20 A curve 400V tripping class C (refer to wiring diagram) | |||||