Specifications Table for EWWQ-G-SS

EWWQ090G-SS EWWQ090G-SS000 EWWQ100G-SS EWWQ100G-SS000 EWWQ120G-SS000 EWWQ120G-SS EWWQ130G-SS EWWQ130G-SS000 EWWQ150G-SS000 EWWQ150G-SS EWWQ170G-SS EWWQ170G-SS000 EWWQ190G-SS EWWQ190G-SS000 EWWQ210G-SS EWWQ210G-SS000 EWWQ240G-SS EWWQ240G-SS000 EWWQ300G-SS EWWQ300G-SS000 EWWQ360G-SS EWWQ360G-SS000
Sound pressure level Cooling Nom. dBA 64   67     69 70     72 72   72   74   76   76   77
Refrigerant Circuits Quantity   1   1     1 1     1 1   1   1   1   1   1
  GWP   2,087.5   2,087.5     2,087.5 2,087.5     2,087.5 2,087.5   2,087.5   2,087.5   2,087.5   2,087.5   2,087.5
  Charge kg 10   10     11 11     12 12   15   16   17   19   20
  Type   R-410A   R-410A     R-410A R-410A     R-410A R-410A   R-410A   R-410A   R-410A   R-410A   R-410A
Operation range Condenser Cooling Min. °CDB 25
      Max. °CDB 55
  Evaporator Cooling Min. °CDB -10
      Max. °CDB 15
Cooling capacity Nom. kW 93.7   105.6     119 135.9     150 172.1   193.8   220.7   246.1   314.3   370.4
Power input Cooling Nom. kW 21.3   24     26.9 30.5     33.9 38.9   43.8   50.74   56.1   70.2   84
Sound power level Cooling Nom. dBA 80   83     85 87     88 88   88   90   92   93   93
Refrigerant charge Refrigerant charge-=-Per circuit-=-TCO2Eq TCO2Eq 20.88   20.88     22.96 22.96     25.05 25.05   31.31   33.40   35.49   39.66   41.75
Dimensions Unit Width mm 928   928     928 928     928 928   928   928   928   928   928
    Depth mm 2,432   2,432     2,264 2,264     2,264 2,432   2,432   2,432   2,432   2,432   2,432
    Height mm 1,066   1,066     1,066 1,066     1,066 1,066   1,066   1,066   1,066   1,186   1,186
Compressor Type   Scroll compressor   Scroll compressor     Scroll compressor Scroll compressor     Scroll compressor Scroll compressor   Scroll compressor   Scroll compressor   Scroll compressor   Scroll compressor   Scroll compressor
  Quantity   2   2     2 2     2 2   2   2   2   2   2
Water heat exchanger - condenser Type   Plate heat exchanger   Plate heat exchanger     Plate heat exchanger Plate heat exchanger     Plate heat exchanger Plate heat exchanger   Plate heat exchanger   Plate heat exchanger   Plate heat exchanger   Plate heat exchanger   Plate heat exchanger
  Water flow rate Nom. l/s 5.52   6.23     7.05 8.04     8.87 10.17   11.43   13.02   14.53   18.46   21.81
Capacity control Minimum capacity % 50   43     50 44     50 45   50   43   50   40   50
  Method   Fixed   Fixed     Fixed Fixed     Fixed Fixed   Fixed   Fixed   Fixed   Fixed   Fixed
Weight Operation weight kg 554.9   652.4     781.6 821.4     859 901.4   945.9   1,009.6   1,023.2   1,194.7   1,311.1
  Unit kg 516   606     728 762     795 832   871   921   934   1,083   1,181
Water heat exchanger - evaporator Water flow rate Nom. l/s 4.5   5.07     5.7 6.51     7.18 8.24   9.28   10.57   11.79   15.06   17.74
  Type   Plate heat exchanger   Plate heat exchanger     Plate heat exchanger Plate heat exchanger     Plate heat exchanger Plate heat exchanger   Plate heat exchanger   Plate heat exchanger   Plate heat exchanger   Plate heat exchanger   Plate heat exchanger
  Water volume l 6   8     8 10     12 13   15   17   17   27   34
EER 4.399   4.4     4.424 4.456     4.425 4.424   4.425   4.349   4.387   4.477   4.41
ESEER 5.51   5.52     5.51 5.53     5.51 5.53   5.52   5.52   5.52   5.52   5.52
Power supply Phase   3~   3~     3~ 3~     3~ 3~   3~   3~   3~   3~   3~
  Frequency Hz 50   50     50 50     50 50   50   50   50   50   50
  Voltage V 400   400     400 400     400 400   400   400   400   400   400
Notes (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.   (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.     (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation. (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.     (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation. (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.   (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.   (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.   (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.   (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.   (1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
  (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation   (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation     (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation     (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation   (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation   (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation   (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation   (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation   (2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
  (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units   (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units     (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units     (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units   (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units   (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units   (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units   (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units   (3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
  (4) - Fluid: Water   (4) - Fluid: Water     (4) - Fluid: Water (4) - Fluid: Water     (4) - Fluid: Water (4) - Fluid: Water   (4) - Fluid: Water   (4) - Fluid: Water   (4) - Fluid: Water   (4) - Fluid: Water   (4) - Fluid: Water
  (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).   (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).     (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS). (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).     (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS). (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).   (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).   (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).   (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).   (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).   (5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
  (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.   (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.     (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.     (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.   (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.   (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.   (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.   (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.   (6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
  (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.   (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.     (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.     (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.   (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.   (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.   (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.   (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.   (7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
  (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load   (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load     (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load     (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load   (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load   (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load   (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load   (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load   (8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
  (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current   (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current     (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current     (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current   (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current   (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current   (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current   (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current   (9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
  (10) - Maximum running current is based on max compressor absorbed current in its envelope   (10) - Maximum running current is based on max compressor absorbed current in its envelope     (10) - Maximum running current is based on max compressor absorbed current in its envelope (10) - Maximum running current is based on max compressor absorbed current in its envelope     (10) - Maximum running current is based on max compressor absorbed current in its envelope (10) - Maximum running current is based on max compressor absorbed current in its envelope   (10) - Maximum running current is based on max compressor absorbed current in its envelope   (10) - Maximum running current is based on max compressor absorbed current in its envelope   (10) - Maximum running current is based on max compressor absorbed current in its envelope   (10) - Maximum running current is based on max compressor absorbed current in its envelope   (10) - Maximum running current is based on max compressor absorbed current in its envelope
  (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.   (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.     (11) - Maximum unit current for wires sizing is based on minimum allowed voltage. (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.     (11) - Maximum unit current for wires sizing is based on minimum allowed voltage. (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.   (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.   (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.   (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.   (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.   (11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
  (12) - Maximum current for wires sizing: compressor full load ampere x 1.1   (12) - Maximum current for wires sizing: compressor full load ampere x 1.1     (12) - Maximum current for wires sizing: compressor full load ampere x 1.1 (12) - Maximum current for wires sizing: compressor full load ampere x 1.1     (12) - Maximum current for wires sizing: compressor full load ampere x 1.1 (12) - Maximum current for wires sizing: compressor full load ampere x 1.1   (12) - Maximum current for wires sizing: compressor full load ampere x 1.1   (12) - Maximum current for wires sizing: compressor full load ampere x 1.1   (12) - Maximum current for wires sizing: compressor full load ampere x 1.1   (12) - Maximum current for wires sizing: compressor full load ampere x 1.1   (12) - Maximum current for wires sizing: compressor full load ampere x 1.1
Weight Unit kg   516   606 728     762 795     832   871   921   934   1083   1181
  Operation weight kg   554.9   652.4 781.6     821.4 859     901.4   945.9   1,009.6   1,023.2   1,194.7   1,311.1
Refrigerant Charge kg   10   10 11     11 12     12   15   16   17   19   20