Specifications Table for FBA-A(9) / RZA-D

FBA71A2VEB / FBA71A2VEB / FBA71A2VEB / RZA200D7Y1B FBA100A2VEB / FBA100A2VEB / RZA200D7Y1B FBA71A2VEB9 / FBA71A2VEB9 / FBA71A2VEB9 / RZA200D7Y1B FBA50A2VEB9 / FBA50A2VEB9 / FBA50A2VEB9 / FBA50A2VEB9 / RZA200D7Y1B FBA60A2VEB9 / FBA60A2VEB9 / FBA60A2VEB9 / RZA200D7Y1B FBA125A2VEB / FBA125A2VEB / RZA250D7Y1B FBA60A2VEB9 / FBA60A2VEB9 / FBA60A2VEB9 / FBA60A2VEB9 / RZA250D7Y1B
Cooling capacity Nom. kW 19.0 (1) 19.0 (1) 19.0 (1) 19.0 (1) 19.0 (1) 22.0 (1) 22.0 (1)
Space cooling SEER   6.38 6.32 6.38 6.51 6.32 6.65 6.69
  ηs,c %   250 252
  Annual energy consumption kWh/a 1,787 1,804 1,787 1,751 1,804 1,985 1,974
  Capacity Pdesign kW 19.0 19.0 19.0 19.0 19.0 22.0 22.0
Space heating (Average climate) Capacity Pdesign kW 11.2 11.2 11.2 11.2 11.2 12.1 12.1
  SCOP/A   4.10 4.10 4.10 4.20 4.10 4.10 4.33
  Annual energy consumption kWh/a 3,824 3,824 3,824 3,733 3,825 4,132 3,916
  ηs,h %   161 161
Heating capacity Nom. kW 22.4 (2) 22.4 (2) 22.4 (2) 22.4 (2) 22.4 (2) 24.0 (2) 24.0 (2)
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.