| FDXM50F3V1B / RXS50L2V1B | FDXM60F3V1B / RXS60L2V1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 5.00 | 6.00 | |
| Space cooling | SEER | 5.72 | 5.51 | ||
| Annual energy consumption | kWh/a | 306 | 381 | ||
| Capacity | Pdesign | kW | 5.00 | 6.00 | |
| Energy efficiency class | A+ | A | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 4.00 | 4.60 |
| SCOP/A | 3.93 | 3.80 | |||
| Energy efficiency class | A | A | |||
| Annual energy consumption | kWh/a | 1,425 | 1,693 | ||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 |
| Gas | OD | mm | 12.70 | 12.70 | |
| Drain | OD | mm | VP20 (External dia.26, Internal dia. 20) | VP20 (External dia.26, Internal dia. 20) | |
| Nominal efficiency | EER | 3.03 | 2.91 | ||
| Annual energy consumption | kWh | 825 | 1,030 | ||
| COP | 3.10 | 3.21 | |||
| Energy labeling Directive | Cooling | B | C | ||
| Heating | D | C | |||
| Heating capacity | Nom. | kW | 5.80 | 7.00 | |
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||