| FDXS25F2VEB / RXS25K3V1B | FDXS35F2VEB / RXS35K2V1B | FDXS50F2VEB / RXS50K2V1B | ||||
|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.4 | 1.7 | |
| Max. | kW | 3.0 | 3.8 | 5.3 | ||
| Nom. | kW | 2.4 (2) | 3.4 (2) | 5.0 (2) | ||
| Space cooling | SEER | 5.08 | 4.82 | 5.12 | ||
| Annual energy consumption | kWh/a | 165 | 247 | 342 | ||
| Capacity | Pdesign | kW | 2.40 | 3.40 | 5.00 | |
| Energy efficiency class | B | B | A | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.60 | 2.90 | 3.50 |
| SCOP/A | 4.19 | 3.81 | 3.41 | |||
| Energy efficiency class | A+ | A | A | |||
| Annual energy consumption | kWh/a | 869 | 1,066 | 1,438 | ||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 |
| Gas | OD | mm | 9.5 | 9.5 | 12.7 | |
| Drain | OD | mm | VP20 (External dia.26, Internal dia. 20) | VP20 (External dia.26, Internal dia. 20) | VP20 (External dia.26, Internal dia. 20) | |
| Nominal efficiency | EER | 3.72 (1) | 3.21 (1) | 3.03 (1) | ||
| Annual energy consumption | kWh | 323 | 530 | 825 | ||
| COP | 3.90 (1) | 3.39 (1) | 3.10 (1) | |||
| Energy labeling Directive | Cooling | A | A | B | ||
| Heating | A | C | D | |||
| Heating capacity | Nom. | kW | 3.2 (3) | 4.0 (3) | 5.8 (3) | |
| Min. | kW | 1.3 | 1.4 | 1.7 | ||
| Max. | kW | 4.5 | 5.0 | 6.0 | ||
| Notes | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | ||||
| (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | ||||
| (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||