Specifications Table for FFA-A / RXM-M9

FFA25A2VEB / RXM25M3V1B9 FFA35A2VEB / RXM35M3V1B9 FFA50A2VEB / RXM50M3V1B9 FFA60A2VEB / RXM60M3V1B9
Cooling capacity Nom. kW 2.50 3.40 5.00 5.70
Space cooling SEER   6.17 6.38 5.98 5.76
  Annual energy consumption kWh/a 142 186 292 347
  Capacity Pdesign kW 2.50 3.40 5.00 5.70
  Energy efficiency class   A++ A++ A+ A+
Space heating (Average climate) Capacity Pdesign kW 2.31 3.10 3.84 3.96
  SCOP/A   4.24 4.10 3.90 4.04
  Energy efficiency class   A+ A+ A A+
  Annual energy consumption kWh/a 762 1,058 1,377 1,372
Nominal efficiency EER   4.57 3.81 3.24 3.05
  Annual energy consumption kWh 273 446 771 934
  COP   3.90 3.50 3.49 3.41
  Energy labeling Directive Cooling   A A A B
    Heating   A B B B
Heating capacity Nom. kW 3.20 4.20 5.80 7.00
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.