| FFQ25B9V1B / RXS25K2V1B | FFQ25B9V1B / RXS25K3V1B | FFQ35B9V1B / RXS35K2V1B | FFQ50B9V1B / RXS50K2V1B | ||||
|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 2.50 (3) | 2.50 (3) | 3.4 (3) | 4.7 (3) | |
| Space cooling | SEER | 4.36 | 4.53 | 5.14 | |||
| Annual energy consumption | kWh/a | 201 | 270 | 334 | |||
| Capacity | Pdesign | kW | 2.50 | 3.50 | 4.90 | ||
| Energy efficiency class | C | C | A | ||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.80 | 2.90 | 4.50 | |
| SCOP/A | 3.75 | 3.49 | 3.41 | ||||
| Energy efficiency class | A | A | A | ||||
| Annual energy consumption | kWh/a | 1,046 | 1,162 | 1,847 | |||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | ||
| Gas | OD | mm | 9.5 | 12.7 | |||
| Drain | OD | mm | VP20 (External dia.26, Internal dia. 20) | VP20 (External dia.26, Internal dia. 20) | |||
| Nominal efficiency | EER | 3.43 | 3.43 | 2.62 | 2.61 | ||
| Annual energy consumption | kWh | 365 | 365 | 650 | 900 | ||
| COP | 3.48 | 3.48 | 2.81 | 2.81 | |||
| Energy labeling Directive | Cooling | A | A | D | D | ||
| Heating | B | B | D | D | |||
| Heating capacity | Nom. | kW | 3.20 (4) | 3.20 (4) | 4.5 (4) | 5.5 (4) | |
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | |||||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | |||||||
| (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||||