| FHA35AVEB / RXM35M3V1B9 | FHA50AVEB / RXM50M3V1B9 | FHA60AVEB / RXM60M3V1B9 | ||||
|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 3.40 | 5.00 | 5.70 | |
| Space cooling | SEER | 6.24 | 5.92 | 6.08 | ||
| Annual energy consumption | kWh/a | 191 | 295 | 328 | ||
| Capacity | Pdesign | kW | 3.40 | 5.00 | 5.70 | |
| Energy efficiency class | A++ | A+ | A+ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 3.10 | 4.35 | 4.71 |
| SCOP/A | 4.43 | 3.86 | 3.87 | |||
| Energy efficiency class | A+ | A | A | |||
| Annual energy consumption | kWh/a | 979 | 1,578 | 1,704 | ||
| Nominal efficiency | EER | 3.73 | 3.21 | 3.29 | ||
| Annual energy consumption | kWh | 456 | 780 | 867 | ||
| COP | 4.08 | 3.35 | 3.32 | |||
| Energy labeling Directive | Cooling | A | B | A | ||
| Heating | A | C | C | |||
| Heating capacity | Nom. | kW | 4.00 | 6.00 | 7.20 | |
| Notes | (1) - See separate drawing for electrical data | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | |||
| (2) - See separate drawing for operation range | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | ||||
| (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||