FNA25A2VEB / RXM25M3V1B9 |
FNA35A2VEB / RXM35M3V1B9 |
FNA50A2VEB / RXM50M3V1B9 |
FNA60A2VEB / RXM60M3V1B9 |
Cooling capacity
|
Nom.
|
kW
|
2.60
|
3.40
|
5.00
|
6.00
|
Space cooling
|
SEER
|
|
5.68
|
5.70
|
5.77
|
5.56
|
|
Annual energy consumption
|
kWh/a
|
160
|
209
|
303
|
378
|
|
Capacity
|
Pdesign
|
kW
|
2.60
|
3.40
|
5.00
|
6.00
|
|
Energy efficiency class
|
|
A+
|
A+
|
A+
|
A
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
2.80
|
2.90
|
4.00
|
4.60
|
|
SCOP/A
|
|
4.24
|
4.05
|
4.09
|
4.16
|
|
Energy efficiency class
|
|
A+
|
A+
|
A+
|
A+
|
|
Annual energy consumption
|
kWh/a
|
924
|
1,002
|
1,369
|
1,547
|
Nominal efficiency
|
EER
|
|
3.80
|
3.09
|
3.38
|
2.70
|
|
Annual energy consumption
|
kWh
|
342
|
551
|
739
|
1,111
|
|
COP
|
|
4.00
|
3.48
|
3.34
|
3.11
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
B
|
A
|
D
|
|
|
Heating
|
|
A
|
B
|
C
|
D
|
Heating capacity
|
Nom.
|
kW
|
3.20
|
4.00
|
5.80
|
7.00
|
Notes
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for operation range
|
(1) - See separate drawing for operation range
|
|
(2) - See separate drawing for operation range
|
(2) - See separate drawing for operation range
|
(2) - See separate drawing for electrical data
|
(2) - See separate drawing for electrical data
|
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|