Specifications Table for FNA-A / RXM-M9

FNA25A2VEB / RXM25M3V1B9 FNA35A2VEB / RXM35M3V1B9 FNA50A2VEB / RXM50M3V1B9 FNA60A2VEB / RXM60M3V1B9
Cooling capacity Nom. kW 2.60 3.40 5.00 6.00
Space cooling SEER   5.68 5.70 5.77 5.56
  Annual energy consumption kWh/a 160 209 303 378
  Capacity Pdesign kW 2.60 3.40 5.00 6.00
  Energy efficiency class   A+ A+ A+ A
Space heating (Average climate) Capacity Pdesign kW 2.80 2.90 4.00 4.60
  SCOP/A   4.24 4.05 4.09 4.16
  Energy efficiency class   A+ A+ A+ A+
  Annual energy consumption kWh/a 924 1,002 1,369 1,547
Nominal efficiency EER   3.80 3.09 3.38 2.70
  Annual energy consumption kWh 342 551 739 1,111
  COP   4.00 3.48 3.34 3.11
  Energy labeling Directive Cooling   A B A D
    Heating   A B C D
Heating capacity Nom. kW 3.20 4.00 5.80 7.00
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.