| FNA25A2VEB9 / RXM25N5V1B9 | FNA25A2VEB9 / RXM25N2V1B9 | FNA35A2VEB9 / RXM35N2V1B9 | FNA35A2VEB9 / RXM35N5V1B9 | FNA50A2VEB9 / RXM50N2V1B9 | FNA60A2VEB9 / RXM60N2V1B9 | ||||
|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 2.60 | 2.60 | 3.40 | 3.40 | 5.00 | 6.00 | |
| Space cooling | SEER | 5.68 | 5.68 | 5.70 | 5.70 | 5.77 | 5.56 | ||
| Annual energy consumption | kWh/a | 160 | 160 | 209 | 209 | 303 | 378 | ||
| Capacity | Pdesign | kW | 2.60 | 2.60 | 3.40 | 3.40 | 5.00 | 6.00 | |
| Energy efficiency class | A+ | A+ | A+ | A+ | A+ | A | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.80 | 2.80 | 2.90 | 2.90 | 4.00 | 4.60 |
| SCOP/A | 4.24 | 4.24 | 4.05 | 4.05 | 4.09 | 4.16 | |||
| Energy efficiency class | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Annual energy consumption | kWh/a | 924 | 924 | 1,002 | 1,002 | 1,368 | 1,547 | ||
| Nominal efficiency | EER | 3.80 | 3.80 | 3.09 | 3.09 | 3.38 | 2.70 | ||
| Annual energy consumption | kWh | 342 | 342 | 550 | 550 | 740 | 1,111 | ||
| COP | 4.00 | 4.00 | 3.48 | 3.48 | 3.34 | 3.11 | |||
| Energy labeling Directive | Cooling | A | A | B | B | A | D | ||
| Heating | A | A | B | B | C | D | |||
| Heating capacity | Nom. | kW | 3.20 | 3.20 | 4.00 | 4.00 | 5.80 | 7.00 | |
| Notes | (1) - See separate drawing for electrical data | (1) - See separate drawing for electrical data | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - See separate drawing for operation range | (2) - See separate drawing for operation range | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||