Specifications Table for FTXF-A / RXF-B

FTXF50A2V1B / RXF50B2V1B FTXF50A2V1B / RXF50B5V1B FTXF60A2V1B / RXF60B2V1B FTXF60A2V1B / RXF60B5V1B
Cooling capacity Min. kW 1.70 1.70 1.70 1.70
  Max. kW 6.00 6.00 7.00 7.00
  Nom. kW 5.00 5.00 6.00 6.00
Space cooling SEER   6.21 6.21 6.15 6.15
  Annual energy consumption kWh/a 282 282 342 342
  Capacity Pdesign kW 5.00 5.00 6.00 6.00
  Energy efficiency class   A++ A++ A++ A++
Space heating (Average climate) Capacity Pdesign kW 4.60 4.60 4.80 4.80
  SCOP/A   4.06 4.06 4.06 4.06
  Energy efficiency class   A+ A+ A+ A+
  Pdh Heating capacity at -10° kW 4.12 4.12 4.24 4.24
  Annual energy consumption kWh/a 1,585 1,585 1,653 1,653
Nominal efficiency Annual energy consumption kWh 751 751 923 923
  EER   3.33 3.33 3.25 3.25
  COP   3.71 3.71 3.93 3.93
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Heating capacity Nom. kW 6.00 6.00 6.40 6.40
  Min. kW 1.70 1.70 1.70 1.70
  Max. kW 7.70 7.70 8.00 8.00
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data