| FTXG25LV1BS / RXLG25M2V1B | FTXG35LV1BS / RXLG35M2V1B | ||||
|---|---|---|---|---|---|
| Outdoor unit | RXLG25M | RXLG35M | |||
| Cooling capacity | Min. | kW | 1.3 | 1.4 | |
| Nom. | kW | 2.5 | 3.5 | ||
| Max. | kW | 4.0 | 4.6 | ||
| Heating capacity | Min. | kW | 1.0 | 1.0 | |
| Nom. | kW | 4.4 | 5.1 | ||
| Max. | kW | 6.1, 3.6 | 6.7, 4.2 | ||
| Nominal efficiency | EER | 3.68 | 3.57 | ||
| COP | 4.31 | 3.89 | |||
| Annual energy consumption | kWh | 340 | 490 | ||
| Energy labeling Directive | Cooling | A | A | ||
| Heating | A | A | |||
| Piping connections | Drain | OD | mm | 18 | 18 |
| Gas | OD | mm | 9.5 | 9.5 | |
| Liquid | OD | mm | 6.35 | 6.35 | |
| Space cooling | Energy efficiency class | A++ | A++ | ||
| Capacity | Pdesign | kW | 2.50 | 3.50 | |
| SEER | 7.04 | 6.67 | |||
| Annual energy consumption | kWh/a | 124 | 184 | ||
| Space heating (Average climate) | Energy efficiency class | A++ | A++ | ||
| Capacity | Pdesign | kW | 2.50 | 3.00 | |
| SCOP/A | 4.64 | 4.60 | |||
| Annual energy consumption | kWh/a | 755 | 913 | ||
| Notes | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||
| (3) - 220V | (3) - 220V | ||||
| (4) - 230V | (4) - 230V | ||||
| (5) - 240V | (5) - 240V | ||||
| (6) - For rated minimal heating capacity indoor unit fan set to SL tap | (6) - For rated minimal heating capacity indoor unit fan set to SL tap | ||||
| (7) - Maximum heating capacity at -15°C outdoor temperature | (7) - Maximum heating capacity at -15°C outdoor temperature | ||||