| FTXJ20MV1BW / FTXJ20MV1BW / 3MXM40A2V1B8 | ||||
|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 4.00 | |
| Heating capacity | Nom. | kW | 4.60 | |
| Nominal efficiency | EER | 4.15 | ||
| COP | 3.95 | |||
| Annual energy consumption | kWh | 482 | ||
| Energy labeling Directive | Cooling | A | ||
| Heating | A | |||
| Space cooling | Energy efficiency class | A++ | ||
| Capacity | Pdesign | kW | 4.00 | |
| SEER | 7.63 | |||
| Annual energy consumption | kWh/a | 184 | ||
| Space heating (Average climate) | Energy efficiency class | A+ | ||
| Capacity | Pdesign | kW | 4.80 | |
| SCOP/A | 4.12 | |||
| Pdh Heating capacity at -10° | kW | 3.58 | ||
| Annual energy consumption | kWh/a | 1,632 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | ||||