| FTXM42M2V1B / RXM42N2V1B | FTXM50M2V1B / RXM50N2V1B | FTXM60M2V1B / RXM60N2V1B | FTXM71M2V1B / RXM71N2V1B | ||||
|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.70 | 1.70 | 1.90 | 2.30 | |
| Max. | kW | 5.00 | 5.30 | 6.70 | 8.50 | ||
| Nom. | kW | 4.20 | 5.00 | 6.00 | 7.10 | ||
| Space cooling | SEER | 7.50 | 7.33 | 6.90 | 6.11 | ||
| Annual energy consumption | kWh/a | 196 | 239 | 304 | 407 | ||
| Capacity | Pdesign | kW | 4.20 | 5.00 | 6.00 | 7.10 | |
| Energy efficiency class | A++ | A++ | A++ | A++ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 4.00 | 4.60 | 4.60 | 6.20 |
| SCOP/A | 4.60 | 4.60 | 4.30 | 3.81 | |||
| Energy efficiency class | A++ | A++ | A+ | A | |||
| Pdh Heating capacity at -10° | kW | 3.68 | 4.09 | 4.09 | 5.01 | ||
| Annual energy consumption | kWh/a | 1,216 | 1,400 | 1,496 | 2,276 | ||
| Nominal efficiency | Annual energy consumption | kWh | 1,170 | ||||
| EER | 3.75 | 3.68 | 3.39 | 3.03 | |||
| COP | 4.12 | 4.00 | 3.61 | 3.19 | |||
| Energy labeling Directive | Cooling | A | A | A | B | ||
| Heating | A | A | A | D | |||
| Heating capacity | Nom. | kW | 5.40 | 5.80 | 7.00 | 8.20 | |
| Min. | kW | 1.70 | 1.70 | 1.70 | 2.30 | ||
| Max. | kW | 6.00 | 6.50 | 8.00 | 10.20 | ||
| Notes | (1) - See separate drawing for electrical data | (1) - See separate drawing for electrical data | (1) - See separate drawing for electrical data | (1) - When normally running: +22°C / + 32°C | |||
| (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - See separate drawing for electrical data | ||||