| FTXP20K3V1B / RXP20K3V1B | FTXP25K3V1B / RXP25K3V1B | FTXP35K3V1B / RXP35K3V1B | FTXP50K3V1B / RXP50K3V1B | FTXP60K3V1B / RXP60K3V1B | FTXP71K3V1B / RXP71K3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Outdoor unit | RXP20K3V1B | RXP25K3V1B | RXP35K3V1B | RXP50K3V1B | RXP60K3V1B | RXP71K3V1B | |||
| Cooling capacity | Nom. | kW | 2.00 | 2.50 | 3.50 | 5.0 | 6.0 | 7.1 | |
| Heating capacity | Nom. | kW | 2.50 | 3.00 | 4.00 | 6.0 | 7.0 | 8.2 | |
| Nominal efficiency | EER | 4.02 | 3.83 | 3.48 | 3.61 | 3.29 | 2.64 | ||
| COP | 4.77 | 4.36 | 4.02 | 3.80 | 3.63 | 3.19 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | D | ||
| Heating | A | A | A | A | A | D | |||
| Space cooling | Energy efficiency class | A++ | A++ | A++ | A++ | A++ | A | ||
| Capacity | Pdesign | kW | 2.00 | 2.50 | 3.50 | 5.00 | 6.00 | 7.10 | |
| SEER | 6.79 | 6.92 | 6.64 | 6.72 | 6.82 | 5.30 | |||
| Annual energy consumption | kWh/a | 103 | 126 | 185 | 260 | 308 | 469 | ||
| Space heating (Average climate) | Energy efficiency class | A++ | A++ | A++ | A+ | A+ | A | ||
| Capacity | Pdesign | kW | 2.20 | 2.40 | 2.80 | 4.60 | 4.80 | 6.20 | |
| SCOP/A | 4.65 | 4.61 | 4.64 | 4.10 | 4.10 | 3.81 | |||
| Pdh Heating capacity at -10° | kW | 2 | 2 | 2 | 4.07 | 4.12 | 4.89 | ||
| Annual energy consumption | kWh/a | 662 | 728 | 845 | 1571 | 1640 | 2279 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||||||