Specifications Table for FTXP-M / RXP-L

FTXP35M5V1B / RXP35L2V1B FTXP35M5V1B / RXP35L5V1B FTXP50M2V1B / RXP50L2V1B FTXP60M2V1B / RXP60L2V1B FTXP71M2V1B / RXP71L2V1B
Outdoor unit RXP35L2V1B RXP35L5V1B
Cooling capacity Min. kW 1.3 1.3 1.7 1.7 2.3
  Nom. kW 3.50 3.50 5.0 6.0 7.1
  Max. kW 4.0 4.0 6.0 7.0 7.3
Heating capacity Min. kW 1.30 1.30 1.7 1.7 2.3
  Nom. kW 4.00 4.00 6.0 7.0 8.2
  Max. kW 4.80 4.80 7.70 8.00 9.00
Nominal efficiency Annual energy consumption kWh     693 912 1,345
  COP   4.02 4.02 3.80 3.63 3.19
  EER   3.49 3.49 3.61 3.29 2.64
  Energy labeling Directive Cooling   A A
    Heating   A A
Space cooling Annual energy consumption kWh/a 186 186 261 308 469
  Energy efficiency class   A++ A++ A++ A++ A
  Capacity Pdesign kW 3.50 3.50 5.00 6.00 7.10
  SEER   6.62 6.62 6.72 6.82 5.30
Space heating (Average climate) Annual energy consumption kWh/a 845 845 1,570 1,637 2,278
  Capacity Pdesign kW 2.80 2.80 4.60 4.80 6.20
  Energy efficiency class   A++ A++ A+ A+ A
  Pdh Heating capacity at -10° kW 2.33 2.33 4.12 4.24 5.02
  SCOP/A   4.64 4.64 4.10 4.10 3.81
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data