Specifications Table for FTXP-N / RXP-N

FTXP20N5V1B / RXP20N5V1B FTXP25N5V1B / RXP25N5V1B FTXP35N5V1B / RXP35N5V1B FTXP50N2V1B / RXP50N5V1B FTXP60N2V1B / RXP60N5V1B FTXP71N2V1B / RXP71N5V1B
Outdoor unit RXP20N5V1B RXP25N5V1B RXP35N5V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.7 1.7 2.3
  Nom. kW 2.00 2.50 3.50 5.0 6.0 7.1
  Max. kW 2.6 3.0 4.0 6.0 7.0 7.3
Heating capacity Min. kW 1.30 1.30 1.30 1.7 1.7 2.3
  Nom. kW 2.50 3.00 4.00 6.0 7.0 8.2
  Max. kW 3.50 4.00 4.80 7.7 8.0 9.0
Nominal efficiency Annual energy consumption kWh       693 912 1,345
  COP   4.77 4.36 4.02 3.80 3.63 3.19
  EER   3.75 3.75 3.26 3.61 3.29 2.64
  Energy labeling Directive Cooling   A A A A A D
    Heating   A A A A A D
Space cooling Annual energy consumption kWh/a 97 121 170 240 308 401
  Energy efficiency class   A++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 2.00 2.50 3.50 5.0 6.0 7.1
  SEER   7.20 7.20 7.20 7.30 6.82 6.20
Space heating (Average climate) Annual energy consumption kWh/a 663 728 845 1,463 1,638 2,166
  Capacity Pdesign kW 2.20 2.40 2.80 4.60 4.80 6.20
  Energy efficiency class   A++ A++ A++ A+ A+ A+
  Pdh Heating capacity at -10° kW 1.99 2.09 2.35 3.15 3.29 4.24
  SCOP/A   4.65 4.61 4.64 4.40 4.10 4.01
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data