Specifications Table for FTXP-N / RXP-N9

FTXP20N5V1B / RXP20N5V1B9 FTXP25N5V1B / RXP25N5V1B9 FTXP35N5V1B / RXP35N5V1B9 FTXP50N2V1B / RXP50N5V1B9 FTXP60N2V1B / RXP60N5V1B9 FTXP71N2V1B / RXP71N5V1B9
Outdoor unit RXP20N5V1B9 RXP25N5V1B9 RXP35N5V1B9
Cooling capacity Min. kW 1.3 1.3 1.3 1.7 1.7 2.3
  Nom. kW 2 2.5 3.5 5 6 7.1
  Max. kW 2.6 3 4 6 7 7.3
Heating capacity Min. kW 1.3 1.3 1.3 1.7 1.7 2.3
  Nom. kW 2.5 3 4 6 7 8.2
  Max. kW 3.5 4 4.8 7.7 8 9
Nominal efficiency EER   3.75 3.75 3.26 3.61 3.29 2.64
  COP   4.77 4.36 4.02 3.8 3.63 3.19
  Annual energy consumption kWh       693 912 1345
  Energy labeling Directive Cooling   A A A A A D
    Heating   A A A A A D
Space cooling Energy efficiency class   A++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 2 2.5 3.5 5 6 7.1
  SEER   7.2 7.2 7.2 7.3 6.82 6.2
  Annual energy consumption kWh/a 97 121 170 240 308 401
Space heating (Average climate) Energy efficiency class   A++ A++ A++ A+ A+ A+
  Capacity Pdesign kW 2.2 2.4 2.8 4.6 4.8 6.2
  SCOP/A   4.65 4.61 4.64 4.4 4.1 4.01
  Pdh Heating capacity at -10° kW 1.99 2.09 2.35 3.15 3.29 4.24
  Annual energy consumption kWh/a 663 728 845 1463 1638 2166
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data