FTXP20N5V1B / RXP20N5V1B9 |
FTXP25N5V1B / RXP25N5V1B9 |
FTXP35N5V1B / RXP35N5V1B9 |
FTXP50N2V1B / RXP50N5V1B9 |
FTXP60N2V1B / RXP60N5V1B9 |
FTXP71N2V1B / RXP71N5V1B9 |
Outdoor unit
|
RXP20N5V1B9
|
RXP25N5V1B9
|
RXP35N5V1B9
|
Cooling capacity
|
Min.
|
kW
|
1.3
|
1.3
|
1.3
|
1.7
|
1.7
|
2.3
|
|
Nom.
|
kW
|
2
|
2.5
|
3.5
|
5
|
6
|
7.1
|
|
Max.
|
kW
|
2.6
|
3
|
4
|
6
|
7
|
7.3
|
Heating capacity
|
Min.
|
kW
|
1.3
|
1.3
|
1.3
|
1.7
|
1.7
|
2.3
|
|
Nom.
|
kW
|
2.5
|
3
|
4
|
6
|
7
|
8.2
|
|
Max.
|
kW
|
3.5
|
4
|
4.8
|
7.7
|
8
|
9
|
Nominal efficiency
|
EER
|
|
3.75
|
3.75
|
3.26
|
3.61
|
3.29
|
2.64
|
|
COP
|
|
4.77
|
4.36
|
4.02
|
3.8
|
3.63
|
3.19
|
|
Annual energy consumption
|
kWh
|
|
|
|
693
|
912
|
1345
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
A
|
A
|
A
|
D
|
|
|
Heating
|
|
A
|
A
|
A
|
A
|
A
|
D
|
Space cooling
|
Energy efficiency class
|
|
A++
|
A++
|
A++
|
A++
|
A++
|
A++
|
|
Capacity
|
Pdesign
|
kW
|
2
|
2.5
|
3.5
|
5
|
6
|
7.1
|
|
SEER
|
|
7.2
|
7.2
|
7.2
|
7.3
|
6.82
|
6.2
|
|
Annual energy consumption
|
kWh/a
|
97
|
121
|
170
|
240
|
308
|
401
|
Space heating (Average climate)
|
Energy efficiency class
|
|
A++
|
A++
|
A++
|
A+
|
A+
|
A+
|
|
Capacity
|
Pdesign
|
kW
|
2.2
|
2.4
|
2.8
|
4.6
|
4.8
|
6.2
|
|
SCOP/A
|
|
4.65
|
4.61
|
4.64
|
4.4
|
4.1
|
4.01
|
|
Pdh Heating capacity at -10°
|
kW
|
1.99
|
2.09
|
2.35
|
3.15
|
3.29
|
4.24
|
|
Annual energy consumption
|
kWh/a
|
663
|
728
|
845
|
1463
|
1638
|
2166
|
Notes
|
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for electrical data
|
(3) - See separate drawing for electrical data
|
(3) - See separate drawing for electrical data
|