Specifications Table for FTXP-N9 / RXP-N8

FTXP50N5V1B9 / RXP50N5V1B8
Cooling capacity Min. kW 1.7
  Nom. kW 5
  Max. kW 5.3
Heating capacity Min. kW 1.7
  Nom. kW 5.6
  Max. kW 6.5
Nominal efficiency EER   3.3
  COP   3.71
  Annual energy consumption kWh 758
  Energy labeling Directive Cooling   A
    Heating   A
Space cooling Energy efficiency class   A++
  Capacity Pdesign kW 5
  SEER   7.1
  Annual energy consumption kWh/a 246
Space heating (Average climate) Energy efficiency class   A+
  Capacity Pdesign kW 4.6
  SCOP/A   4.3
  Pdh Heating capacity at -10° kW 3.73
  Annual energy consumption kWh/a 1498
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data