Specifications Table for FVA-A / RZASG-MV1

FVA100AMVEB / RZASG100M7V1B FVA71AMVEB / RZASG71M2V1B FVA125AMVEB / RZASG125M7V1B FVA140AMVEB / RZASG140M7V1B FVA71AMVEB / FVA71AMVEB / RZASG140M7V1B
Cooling capacity Nom. kW   6.80 (1) 12.1 (1) 13.4 (1)
Space cooling SEER     5.83 5.52 5.63
  Annual energy consumption kWh/a   408 1,314 1,428
  Capacity Pdesign kW   6.80 12.1 13.4
  Energy efficiency class     A+
Space heating (Average climate) Capacity Pdesign kW   4.50 6.00 7.80
  SCOP/A     4.04 3.64 3.81
  Energy efficiency class     A+
  Annual energy consumption kWh/a   1,559 2,308 2,866
Heating capacity Nom. kW   7.50 (2) 13.5 (2) 15.5 (2)
Cooling capacity Nom. kW 9.5       13.4
Heating capacity Nom. kW 10.8       15.5
Space cooling Energy efficiency class   A+
  Capacity Pdesign kW 9.5       13.4
  SEER   5.72       7.71
  Annual energy consumption kWh/a 581       1043
Space heating (Average climate) Energy efficiency class   A
  Capacity Pdesign kW 6       7.80
  SCOP/A   3.83       4.43
  Annual energy consumption kWh/a 2193       2467
Notes   (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
    (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
    (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
    (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data