Specifications Table for FVXM-A / RXM-R

FVXM25A2V1B / RXM25R5V1B FVXM25A3V1B / RXM25R5V1B FVXM35A2V1B / RXM35R5V1B FVXM35A3V1B / RXM35R5V1B FVXM50A2V1B / RXM50R2V1B FVXM50A2V1B / RXM50R5V1B FVXM50A3V1B / RXM50R2V1B FVXM50A3V1B / RXM50R5V1B
Cooling capacity Min. kW 1.30   1.40   1.40 1.40
  Max. kW 3.50   4.00   5.80 5.80
  Nom. kW 2.40   3.40   5.00 5.00
Space cooling SEER   8.55   8.11   7.30 7.30
  Annual energy consumption kWh/a 98   147   240 240
  Capacity Pdesign kW 2.40   3.40   5.00 5.00
  Energy efficiency class   A+++   A++   A++ A++
Space heating (Average climate) Capacity Pdesign kW 2.30   2.80   4.10 4.10
  SCOP/A   4.65   4.63   4.31 4.31
  Energy efficiency class   A++   A++   A+ A+
  Pdh Heating capacity at -10° kW 2.03   2.34   3.58 3.58
  Annual energy consumption kWh/a 693   847   1,330 1,330
Nominal efficiency Annual energy consumption kWh 268   424   656 656
  EER   4.47   4.01   3.81 3.81
  COP   4.55   3.90   3.81 3.81
  Energy labeling Directive Cooling   A   A   A A
    Heating   A   A   A A
Heating capacity Nom. kW 3.40   4.50   5.80 5.80
  Min. kW 1.30   1.40   1.40 1.40
  Max. kW 4.70   5.80   8.10 8.10
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.   (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.   (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.   (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.   (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range   (3) - See separate drawing for operation range   (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data   (4) - See separate drawing for electrical data   (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data
Cooling capacity Min. kW   1.30   1.40     1.40 1.40
  Nom. kW   2.40   3.40     5.00 5.00
  Max. kW   3.50   4.00     5.80 5.80
Heating capacity Min. kW   1.30   1.40     1.40 1.40
  Nom. kW   3.40   4.50     5.80 5.80
  Max. kW   4.70   5.80     8.10 8.10
Nominal efficiency EER     4.47   4.01     3.81 3.81
  COP     4.55   3.90     3.81 3.81
  Annual energy consumption kWh   268   424     656 656
  Energy labeling Directive Cooling     A   A     A A
    Heating     A   A     A A
Space cooling Energy efficiency class     A+++   A++     A++ A++
  Capacity Pdesign kW   2.40   3.40     5.00 5.00
  SEER     8.55   8.11     7.30 7.30
  Annual energy consumption kWh/a   98   147     240 240
Space heating (Average climate) Energy efficiency class     A++   A++     A+ A+
  Capacity Pdesign kW   2.30   2.80     4.10 4.10
  SCOP/A     4.65   4.63     4.31 4.31
  Pdh Heating capacity at -10° kW   2.03   2.34     3.58 3.58
  Annual energy consumption kWh/a   693   847     1,330 1,330