FVXM25B2V1B / RXM25R5V1B9 |
FVXM35B2V1B / RXM35R5V1B9 |
Cooling capacity
|
Min.
|
kW
|
1.3
|
1.4
|
|
Nom.
|
kW
|
2.4
|
3.4
|
|
Max.
|
kW
|
3.5
|
4
|
Heating capacity
|
Min.
|
kW
|
1.3
|
1.4
|
|
Nom.
|
kW
|
3.4
|
4.5
|
|
Max.
|
kW
|
4.7
|
5.8
|
Nominal efficiency
|
EER
|
|
4.47
|
4.01
|
|
COP
|
|
4.55
|
3.9
|
|
Annual energy consumption
|
kWh
|
268
|
424
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
|
|
Heating
|
|
A
|
A
|
Space cooling
|
Energy efficiency class
|
|
A+++
|
A++
|
|
Capacity
|
Pdesign
|
kW
|
2.4
|
3.4
|
|
SEER
|
|
8.55
|
8.11
|
|
Annual energy consumption
|
kWh/a
|
98
|
147
|
Space heating (Average climate)
|
Energy efficiency class
|
|
A++
|
A++
|
|
Capacity
|
Pdesign
|
kW
|
2.3
|
2.8
|
|
SCOP/A
|
|
4.65
|
4.63
|
|
Pdh Heating capacity at -10°
|
kW
|
2.03
|
2.34
|
|
Annual energy consumption
|
kWh/a
|
693
|
847
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|