FVXM25FV1B9 / RXM25R5V1B |
FVXM35FV1B9 / RXM35R5V1B |
FVXM50FV1B9 / RXM50R2V1B |
FVXM50FV1B9 / RXM50R5V1B |
Outdoor unit
|
RXM25R5V1B
|
RXM35R5V1B
|
RXM50R2V1B
|
RXM50R5V1B
|
Cooling capacity
|
Min.
|
kW
|
1.30
|
1.40
|
1.40
|
1.40
|
|
Nom.
|
kW
|
2.50
|
3.50
|
5.00
|
5.00
|
|
Max.
|
kW
|
3.00
|
3.80
|
5.60
|
5.60
|
Heating capacity
|
Min.
|
kW
|
1.30
|
1.40
|
1.40
|
1.40
|
|
Nom.
|
kW
|
3.40
|
4.50
|
5.80
|
5.80
|
|
Max.
|
kW
|
4.50
|
5.00
|
8.10
|
8.10
|
Nominal efficiency
|
Annual energy consumption
|
kWh
|
298
|
545
|
773
|
773
|
|
COP
|
|
4.42
|
3.78
|
3.63
|
3.63
|
|
EER
|
|
4.20
|
3.21
|
3.23
|
3.23
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
A
|
A
|
|
|
Heating
|
|
A
|
A
|
A
|
A
|
Space cooling
|
Annual energy consumption
|
kWh/a
|
120
|
190
|
257
|
257
|
|
Energy efficiency class
|
|
A++
|
A++
|
A++
|
A++
|
|
Capacity
|
Pdesign
|
kW
|
2.50
|
3.50
|
5.00
|
5.00
|
|
SEER
|
|
7.20
|
6.43
|
6.80
|
6.80
|
Space heating (Average climate)
|
Annual energy consumption
|
kWh/a
|
737
|
1,015
|
1,471
|
1,471
|
|
Capacity
|
Pdesign
|
kW
|
2.40
|
2.90
|
4.20
|
4.20
|
|
Energy efficiency class
|
|
A+
|
A+
|
A+
|
A+
|
|
Pdh Heating capacity at -10°
|
kW
|
2.23
|
2.40
|
2.23
|
2.23
|
|
SCOP/A
|
|
4.56
|
4.00
|
4.00
|
4.00
|
Notes
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
|
(2) - See separate drawing for operation range
|
(2) - See separate drawing for operation range
|
(2) - See separate drawing for operation range
|
(2) - See separate drawing for operation range
|
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|