| FWI02AAFN6V3 | FWI04AAFN6V3 | FWI06AAFN6V3 | FWI08AAFN6V3 | |||||
|---|---|---|---|---|---|---|---|---|
| Cooling capacity (standard conditions) | Sensible capacity 4-pipe | Low | kW | 1.46 (1) | 2.10 (1) | 3.34 (1) | 4.50 (1) | |
| High | kW | 2.23 (1) | 3.58 (1) | 5.03 (1) | 7.56 (1) | |||
| Total capacity 4-pipe | Low | kW | 1.85 (1) | 2.62 (1) | 4.61 (1) | 6.09 (1) | ||
| High | kW | 2.60 (1) | 4.41 (1) | 6.61 (1) | 9.50 (1) | |||
| Heating capacity (standard conditions) | Capacity 4-pipe | Low | kW | 2.90 (3) | 3.73 (3) | 7.01 (3) | 8.96 (3) | |
| High | kW | 3.86 (3) | 5.51 (3) | 9.53 (3) | 12.90 (3) | |||
| Power input | Low | kW | 0.007 | 0.009 | 0.014 | 0.025 | ||
| High | kW | 0.018 | 0.067 | 0.036 | 0.150 | |||
| Dimensions | Unit | Height | mm | 298 | 298 | 350 | 350 | |
| Width | mm | 577 | 577 | 793 | 793 | |||
| Depth | mm | 577 | 577 | 793 | 793 | |||
| Weight | Unit | kg | 23.0 | 23.0 | 43.0 | 43.0 | ||
| Decoration panel | Dimensions | Unit | Height | mm | 41 | 41 | 75 | 75 |
| Width | mm | 730 | 730 | 860 | 860 | |||
| Depth | mm | 730 | 730 | 860 | 860 | |||
| Fan | Air flow rate | Low | m³/h | 356 | 395 | 687 | 956 | |
| High | m³/h | 610 | 982 | 1,137 | 1,823 | |||
| Total sound power level | Low | dBA | 35.0 (4) | 38.0 (4) | 35.0 (4) | 43.0 (4) | ||
| High | dBA | 46.0 (4) | 61.0 (4) | 45.0 (4) | 58.0 (4) | |||
| Sound pressure level | Low | dBA | 35.0 (4) | 38.0 (4) | 35.0 (4) | 43.0 (4) | ||
| High | dBA | 46.0 (4) | 61.0 (4) | 45.0 (4) | 58.0 (4) | |||
| Water flow | Cooling | Low | l/h | 317 (1) | 451 (1) | 792 (1) | 1,045 (1) | |
| High | l/h | 447 (1) | 759 (1) | 1,135 (1) | 1,631 (1) | |||
| Heating | High | l/h | 338 (3) | 474 (3) | 834 (3) | 1,133 (3) | ||
| Low | l/h | 254 (3) | 321 (3) | 613 (3) | 785 (3) | |||
| Water pressure drop | Cooling | Low | kPa | 4 (1) | 7 (1) | 12 (1) | 17 (1) | |
| High | kPa | 8 (1) | 25 (1) | 22 (1) | 37 (1) | |||
| Heating | Low | kPa | 6 (3) | 4 (3) | 11 (3) | 18 (3) | ||
| High | kPa | 11 (3) | 11 (3) | 19 (3) | 33 (3) | |||
| Allowed water temperature | Cooling | Min. | °C | 5 | 5 | 5 | 5 | |
| Heating | Max. | °C | 80 | 80 | 80 | 80 | ||
| Piping connections | Water | Inlet | 1/2" | 1/2" | 3/4" | 3/4" | ||
| Outlet | 1/2" | 1/2" | 3/4" | 3/4" | ||||
| Drain | OD | mm | 10 | 10 | 10 | 10 | ||
| Water connections | Primary coil | inch | 1/2" | 1/2" | 3/4" | 3/4" | ||
| Additional coil | inch | 1/2" | 1/2" | 1/2" | 1/2" | |||
| Control systems | Wired remote control | FWEC3A, FWECSA, FWTOUCH | FWEC3A, FWECSA, FWTOUCH | FWEC3A, FWECSA, FWTOUCH | FWEC3A, FWECSA, FWTOUCH | |||
| Power supply | Type | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | |||
| Phase | 1~ | 1~ | 1~ | 1~ | ||||
| Frequency | Hz | 50 | 50 | 50 | 50 | |||
| Voltage | V | 230 | 230 | 230 | 230 | |||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. | ||||
| (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. | (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. | (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. | (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. | |||||
| (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. | (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. | (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. | (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. | |||||
| (4) - Sound power level according to ISO3741 | (4) - Sound power level according to ISO3741 | (4) - Sound power level according to ISO3741 | (4) - Sound power level according to ISO3741 | |||||
| (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. | (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. | (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. | (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. | |||||