| JEHSCU0200CM1 | JEHSCU0250CM1 | JEHSCU0300CM1 | |||||
|---|---|---|---|---|---|---|---|
| Refrigerating capacity | Medium temperature | R-407A | Nom | kW | 3.48 | 4.09 | |
| R-134a | Nom | kW | 2.13 | ||||
| R-407F | Nom | kW | 3.33 | 3.82 | 4.63 | ||
| Parameters at full load and ambient temp. 43°C | R-134a | Te -10°C | Power input (D3) | kW | 1.32 | ||
| Declared COP (COP3) | 1.42 | ||||||
| Cooling capacity (P3) | kW | 1.87 | |||||
| Weight | Unit | kg | 69.7 | 71.7 | 73.7 | ||
| Parameters at full load and ambient temp. 25°C | R-407A | Te -10°C | Declared COP (COP2) | 2.61 | 2.44 | ||
| Power input (D2) | kW | 1.42 | 1.78 | ||||
| Cooling capacity (P2) | kW | 3.72 | 4.35 | ||||
| R-407F | Te -10°C | Power input (D2) | kW | 1.50 | 1.82 | 2.30 | |
| Cooling capacity (P2) | kW | 3.68 | 4.26 | 5.09 | |||
| Declared COP (COP2) | 2.46 | 2.33 | 2.21 | ||||
| R-134a | Te -10°C | Cooling capacity (P2) | kW | 2.25 | |||
| Declared COP (COP2) | 2.21 | ||||||
| Power input (D2) | kW | 1.02 | |||||
| Refrigerant | GWP Type 5 | 1,387 | 1,387 | 1,387 | |||
| GWP Type 2 | 2,107 | 2,107 | |||||
| GWP Type 3 | 1,825 | 1,825 | 1,825 | ||||
| GWP | 1,430 | ||||||
| Type 3 | R-407F | R-407F | R-407F | ||||
| Type 2 | R-407A | R-407A | |||||
| Type 5 | R-448A | R-448A | R-448A | ||||
| Type | R-134a | ||||||
| Parameters at full load and ambient temp. 32°C (Point A) | R-134a | Te -10°C | Rated COP (COPA) | 1.92 | |||
| Rated cooling capacity (PA) | kW | 2.13 | |||||
| Rated power input (DA) | kW | 1.11 | |||||
| R-407F | Te -10°C | Rated COP (COPA) | 1.92 | 1.83 | 1.74 | ||
| Rated cooling capacity (PA) | kW | 3.33 | 3.82 | 4.63 | |||
| Rated power input (DA) | kW | 1.74 | 2.09 | 2.66 | |||
| R-407A | Te -10°C | Rated power input (DA) | kW | 1.60 | 1.98 | ||
| Rated COP (COPA) | 2.18 | 2.06 | |||||
| Rated cooling capacity (PA) | kW | 3.48 | 4.09 | ||||
| Power input | Medium temperature | R-134a | Nom | kW | 1.11 | ||
| R-407F | Nom | kW | 1.74 | 2.09 | 2.66 | ||
| R-407A | Nom | kW | 1.60 | 1.98 | |||
| COP | Medium temperature | R-134a | 1.92 | ||||
| R-407F | 1.92 | 1.83 | 1.74 | ||||
| R-407A | 2.18 | 2.06 | |||||
| Dimensions | Unit | Width | mm | 1,101 | 1,101 | 1,101 | |
| Depth | mm | 444 | 444 | 444 | |||
| Height | mm | 662 | 662 | 662 | |||
| Casing | Colour | Light grey | Light grey | Light grey | |||
| Fan | Type | Axial | Axial | Axial | |||
| Power supply | Phase | 1~ | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 230 | 230 | 230 | |||
| Notes | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | ||||
| (2) - Sound pressure level is measured at 10m in anechoic room | (2) - Sound pressure level is measured at 10m in anechoic room | (2) - Sound pressure level is measured at 10m in anechoic room | |||||
| (3) - Its functioning relies on fluorinated greenhouse gases | (3) - Its functioning relies on fluorinated greenhouse gases | (3) - Its functioning relies on fluorinated greenhouse gases | |||||