RKHBRD011ACV1 |
RKHBRD014ACV1 |
RKHBRD016ACV1 |
Sound pressure level
|
Nom.
|
dBA
|
43 (5), 46 (6)
|
45 (5), 46 (6)
|
46 (5), 46 (6)
|
Refrigerant
|
Charge
|
kg
|
2.6
|
2.6
|
2.6
|
|
Type
|
|
R-134a
|
R-134a
|
R-134a
|
Dimensions
|
Unit
|
Width
|
mm
|
600
|
600
|
600
|
|
|
Depth
|
mm
|
695
|
695
|
695
|
|
|
Height
|
mm
|
705
|
705
|
705
|
Casing
|
Material
|
|
Precoated sheet metal
|
Precoated sheet metal
|
Precoated sheet metal
|
|
Colour
|
|
Metallic grey
|
Metallic grey
|
Metallic grey
|
Weight
|
Unit
|
kg
|
144
|
144
|
144
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
|
Name
|
|
V1
|
V1
|
V1
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
|
Voltage
|
V
|
220-240
|
220-240
|
220-240
|
Current
|
Recommended fuses
|
A
|
25
|
25
|
25
|
Notes
|
(1) - Nominal water flow rate for Dt: 10°C
|
(1) - Nominal water flow rate for Dt: 10°C
|
(1) - Nominal water flow rate for Dt: 10°C
|
|
(2) - Maximum water flow rate for Dt: 5°C
|
(2) - Maximum water flow rate for Dt: 5°C
|
(2) - Maximum water flow rate for Dt: 5°C
|
|
(3) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections.
|
(3) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections.
|
(3) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections.
|
|
(4) - Values are sound pressure values measured at all sides (front, back, left, right, top) at 1m distance. The values do not occur simultaneously on all mentioned sides.
|
(4) - Values are sound pressure values measured at all sides (front, back, left, right, top) at 1m distance. The values do not occur simultaneously on all mentioned sides.
|
(4) - Values are sound pressure values measured at all sides (front, back, left, right, top) at 1m distance. The values do not occur simultaneously on all mentioned sides.
|
|
(5) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB
|
(5) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB
|
(5) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB
|
|
(6) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB
|
(6) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB
|
(6) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB
|
|
(7) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
|
(7) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
|
(7) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
|
|
(8) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
|
(8) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
|
(8) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
|
|
(9) - European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
|
(9) - European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
|
(9) - European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
|