| RXTP25N2V1B9 | RXTP35N2V1B9 | RXP60N5V1B9 | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 49 | 49 | ||
| Cooling | Nom. | dBA | 48 | 48 | |||
| Standard Accessories | Installation manual | 1 | 1 | 1 | |||
| Refrigerant charge label | 1 | 1 | 1 | ||||
| Multilingual fluorinated greenhouse gases labels | 1 | 1 | 1 | ||||
| Refrigerant | Charge | TCO2Eq | 0.75 | 0.75 | |||
| GWP | 675 | 675 | |||||
| Charge | kg | 1.1 | 1.1 | ||||
| Type | R-32 | R-32 | |||||
| Fan motor | Speed | Cooling | Super low | rpm | 450 | 450 | |
| Heating | Super low | rpm | 360 | 360 | |||
| Operation range | Cooling | Ambient | Max. | °CDB | 46 | 46 | |
| Min. | °CDB | -10 | -10 | ||||
| Heating | Ambient | Max. | °CWB | 18 | 18 | ||
| Min. | °CWB | -25 | -25 | ||||
| Piping connections | Level difference | IU - OU | Max. | m | 15 | 15 | |
| Additional refrigerant charge | kg/m | 0.02 (for piping length exceeding 10m) | 0.02 (for piping length exceeding 10m) | ||||
| Dimensions | Unit | Width | mm | 763 | 763 | ||
| Depth | mm | 312 | 312 | ||||
| Height | mm | 551 | 551 | ||||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | ||||
| Weight | Unit | kg | 38 | 38 | |||
| Power supply | Phase | 1~ | 1~ | ||||
| Frequency | Hz | 50 | 50 | ||||
| Voltage | V | 220-240 | 220-240 | ||||
| Notes | (1) - Contains fluorinated greenhouse gases | (1) - Contains fluorinated greenhouse gases | (1) - See separate drawing for operation range | ||||
| (2) - See separate drawing for operation range | (2) - See separate drawing for operation range | (2) - See separate drawing for electrical data | |||||
| (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - Contains fluorinated greenhouse gases | |||||
| Dimensions | Unit | Height | mm | 734 | |||
| Width | mm | 954 | |||||
| Depth | mm | 401 | |||||
| Weight | Unit | kg | 50 | ||||
| Compressor | Type | Hermetically sealed swing compressor | |||||
| Sound pressure level | Cooling | Nom. | dBA | 49 | |||
| Heating | Nom. | dBA | 49 | ||||
| Refrigerant | Type | R-32 | |||||
| Charge | kg | 1.15 | |||||
| Charge | tCO2Eq | 0.78 | |||||
| GWP | 675 | ||||||
| Piping connections | Piping length | OU - IU | Max. | m | 30 | ||
| Additional refrigerant charge | kg/m | 0.02 (for piping length exceeding 10m) | |||||
| Level difference | IU - OU | Max. | m | 20 | |||
| Standard Accessories | Drain cap | 3 | |||||
| Drain plug | 1 | ||||||
| Energy Efficiency Range | A+++ ~ D | ||||||
| Power supply | Phase | 1~ | |||||
| Frequency | Hz | 50 | |||||
| Voltage | V | 220-240 | |||||