| EHSH04P30DA / ERGA04DAV3 | EHSH08P30DA / ERGA06DAV3 | EHSH08P50DA / ERGA06DAV3 | EHSH08P50DA7 / ERGA06DAV3 | EHSH08P30DA / ERGA08DAV3 | EHSH08P50DA / ERGA08DAV3 | EHSH08P50DA7 / ERGA08DAV3 | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Domestic hot water heating | General | Declared load profile | L | L | XL | L | XL | ||||
| Average climate | Water heating energy efficiency class | A | A | A | A | A | |||||
| COP | 5.10 (1), 3.65 (2) | 4.85 (1), 3.50 (2) | 4.85 (1), 3.50 (2) | 4.85, 3.50 | 4.60 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | 4.60, 3.50 | ||||
| Indoor unit | EHSH04P30D | EHSH08P30D | EHSH08P50D | EHSH08P50DA7 | EHSH08P30D | EHSH08P50D | EHSH08P50DA7 | ||||
| Heating capacity | Nom. | kW | 4.30 (1), 4.60 (2) | 6.00 (1), 5.90 (2) | 6.00 (1), 5.90 (2) | 7.50 (1), 7.80 (2) | 7.50 (1), 7.80 (2) | ||||
| Power input | Heating | Nom. | kW | 0.850 (1), 1.26 (2) | 1.24 (1), 1.69 (2) | 1.24 (1), 1.69 (2) | 1.63 (1), 2.23 (2) | 1.63 (1), 2.23 (2) | |||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| Heating capacity | Nom. | kW | 6.00, 5.90 | 7.50, 7.80 | |||||||
| Power input | Heating | Nom. | kW | 1.24, 1.69 | 1.63, 2.23 | ||||||
| Domestic hot water heating | General | Declared load profile | XL | XL | |||||||
| Average climate | Water heating energy efficiency class | A | A | ||||||||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.26 | 3.32 | ||||||
| Seasonal space heating eff. class | A++ | A++ | |||||||||
| Average climate water outlet 35°C | General | SCOP | 4.47 | 4.56 | |||||||
| Seasonal space heating eff. class | A+++ | A+++ | |||||||||
| Energy Efficiency Range | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | |||||||||